m+Medelevator.RU
← Поиск публикаций
Clinical oral implants research · 2002

The relative impact of local and endogenous patient-related factors on implant failure up to the abutment stage.

СтатьяПоддержка исследования: вне правительства СШАНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

van Steenberghe Daniel, Jacobs Reinhilde, Desnyder Mandy, Maffei Gaia, Quirynen Marc

Аннотация

The aim of the present study was to assess the influence of endogenous and local factors on the occurrence of implant failure up to the abutment stage. The study comprised a group of 399 consecutive patients, which represented the total of patients who had been treated from 1995 to 1997 (with a total of 1263 Brånemark Brån-system implants) at the Department of Periodontology of the University Hospital, Catholic University Leuven. For each patient, the medical history was carefully examined. Data collection and analysis were mainly focused on endogenous factors such as hypertension, osteoporosis, hypo- or hyperthyroid function, chemotherapy, diabetes type I or II, Crohn's disease, some local factors (e.g. bone quality, reason for tooth loss) and breach of sterility during surgery. The reason for tooth loss, smoking habits, radiotherapy and other local bone factors (bone quality and quantity) were also recorded. Implant failures were recorded up to the abutment connection. The present study indicated a success rate until this stage of 97.8%. General factors such as heavy smoking, chemotherapy plus poor bone quality increased implant failure rate. Radiotherapy, limited bone volume and claustrophobia, which led to breaching the strict preoperative rules of asepsis, appeared to be the most relevant local factors for early implant failures.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты