Archives of orthopaedic and trauma surgery · 2024

Reconstruction of mechanical leg axis using non-modular cemented hinged prosthesis in complex primary total knee arthroplasty.

СтатьяНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Jacob Benjamin, Jacob Nadja, Röhner Eric, Wassilew Georgi, Matziolis Georg, Heinecke Markus

Аннотация

PURPOSE: Modular cementless knee arthroplasty systems are capable of precise reconstruction of the mechanical axis. However, they are considered more susceptible to complications. In contrast, non-modular cemented systems are said to be more forgiving and show good long-term results. The aim of this study was to investigate the resulting leg axis after implantation of a non-modular cemented rotating hinged knee prosthesis. Furthermore, potential risk factors for the occurrence of malalignment and complications should be identified.

METHODS: Between 2005 and 2015, 115 patients could be included in this monocentric retrospective cohort study. All patients underwent primary hinged non-modular cemented total knee arthroplasty. Preoperative and postoperative standardized long radiographs were analysed to determine resulting leg axis. Furthermore, epidemiological and intraoperative data as well as perioperative complications were surveyed.

RESULTS: Average leg axis was 5.8° varus preoperatively and 0.6° valgus postoperatively. Considering an axis deviation of 3° as the target corridor, 27% of all cases examined were outside the desired range. 21% cases showed a femoral deviation from the target corridor and 15% showed a tibial deviation. There was a significant relationship between the preoperative mLDFA and the mechanical alignment of the femoral component (R = 0.396, p < 0.001) as well as between the preoperative mMPTA and the mechanical alignment of the tibial component (R = 0.187, p = 0.045). The mean operative duration was 96 min. No periprosthetic fractures were observed within the study cohort.

CONCLUSION: The main result of the present work is that a non-modular cemented rotating hinged knee arthroplasty system can reconstruct the mechanical leg axis precisely and comparable to modular cementless and unconstrained total knee prostheses. Component malalignment is primarily dependent upon extraarticular deformity preoperatively. Periprosthetic fracture rates and duration of surgery were lower compared with current literature.

LEVEL OF EVIDENCE: Level III: Retrospective cohort study.