MedElevator Войти в исследования
← Поиск публикаций

DOI 10.3881/j.issn.1000-503x.2015.03.007

Медицинская библиотека · Zhongguo yi xue ke xue yuan xue bao. Acta Academiae Medicinae Sinicae · 2015

Effect of Crosslinks on the Stability of the Spine and the Pedicle Screw Fixation.

Zhang Xiang-Yu, Su Feng, Yan Shi, Zhang Zhi-Min, Zhang Pei-Nan

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

OBJECTIVE

To evaluate the effect of crosslinks on the stability of the spine and pedicle screws.

METHODS

Compression fracture of the L1 vertebra was produced in 30 fresh thoracic and lumbar vertebrae samples obtained from adult sheep, which were divided into 3 groups (n=10)with lot-drawing method. Four screws were fixed onto the superior and inferior pedicles of vertebral arch close to the fractured vertebrae, with different number of crosslinks (0 in Group A,1 in Group B, and 2 in Group C) on the rods. After fixation, the samples were subject to 10 000 times of fatigue test with 1.5 Hz load on the HY-3080 computer-control electronic universal test machine and HY-1000NM computer-control torsion test machine. The axial compressive stiffness, maximum pullout strength,and range of motion (ROM) of 6 directions, i.e., flexion, extension, left and right lateral bending, and left and right axial rotation of the 3 groups were measured and compared.

RESULTS

There were no statistically significant differences in axial compressive stiffness as well as the ROM of flexion, extension, and left and right lateral bending (all P>0.05). The maximum pullout strength was significantly smaller in Group A and Group B than in Group C [(129.56±29.63)N vs.(294.67±23.25) N,P=0.000;(254.02±36.29)vs.(294.67±23.25)N, P=0.006]. The ROM of left axial rotation was the highest in Group A(13.35°±1.06°), followed by Group B(12.23°±1.06°)and Group C (11.04°±0.74°)(F=13.44, P=0.000; Group B vs. Group A, P=0.000; Group B vs. Group C, P=0.001; Group C vs. Group A,P=0.000). The ROM of right axial rotation was also the highest in Group A(13.56°±1.15°), lower in Group B (12.39°±1.01°) and the lowest in Group C (10.81°±0.51°) (F=21.91, P=0.000; Group B vs. Group A,P=0.002; Group B vs. Group C, P=0.001; Group C vs. Group A, P=0.000).

CONCLUSION

Crosslinks may reinforce the pullout strength of the screws and improve the axial stability of the spine.

Для цитирования: Zhang Xiang-Yu, Su Feng, Yan Shi, Zhang Zhi-Min, Zhang Pei-Nan. Effect of Crosslinks on the Stability of the Spine and the Pedicle Screw Fixation.. Zhongguo yi xue ke xue yuan xue bao. Acta Academiae Medicinae Sinicae. 2015. DOI: 10.3881/j.issn.1000-503x.2015.03.007.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.