MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1177/03635465231174910

Медицинская библиотека · The American journal of sports medicine · 2023

Complete Restoration of Native Glenoid Width Improves Glenohumeral Biomechanics After Simulated Latarjet.

Rauck Ryan C, Brusalis Christopher M, Jahandar Amirhossein, Lamplot Joseph D, Dines David M, Warren Russell F, Gulotta Lawrence V, Kontaxis Andreas, Taylor Samuel A

СтатьяПоддержка службы здравоохранения СШАПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

BACKGROUND

The amount of glenoid width that must be restored with a Latarjet procedure in order to reestablish glenohumeral stability has not been determined.

PURPOSE/HYPOTHESIS: The purpose of this article was to determine the percentage of glenoid width restoration necessary for glenohumeral stability after Latarjet by measuring anterior humeral head translation and force distribution on the coracoid graft. The hypothesis was that at least 100% of glenoid width restoration with Latarjet would be required to maintain glenohumeral stability.

STUDY

DESIGN

Controlled laboratory study.

METHODS

Nine cadaveric shoulders were prepared and mounted on an established shoulder simulator. A lesser tuberosity osteotomy (LTO) was performed to allow accurate removal of glenoid bone. Coracoid osteotomy was performed, and the coracoid graft was sized to a depth of 10 mm. Glenoid bone was sequentially removed, and Latarjet was performed using 2 screws to reestablish 110%, 100%, 90%, and 80% of native glenoid width. The graft was passed through a subscapularis muscle split, and the LTO was repaired. A motion tracking system recorded glenohumeral translations, and force distribution was recorded using a TekScan pressure sensor secured to the glenoid face and coracoid graft. Testing conditions included native; LTO; Bankart tear; and 110%, 100%, 90%, and 80% of glenoid width restoration with Latarjet. Glenohumeral translations were recorded while applying an anteroinferior load of 44 N at 90° of humerothoracic abduction and 0° or 45° of glenohumeral external rotation. Force distribution was recorded without an anteroinferior load.

RESULTS

Anterior humeral head translation progressively increased as the proportion of glenoid width restored decreased. A marked increase in anterior humeral head translation was found with 90% versus 100% glenoid width restoration (10.8 ± 3.0 vs 4.1 ± 2.6 mm, respectively; P < .001). Greater glenoid bone loss also led to increased force on the coracoid graft relative to the native glenoid bone after Latarjet. A pronounced increase in force on the coracoid graft was seen with 90% versus 100% glenoid width restoration (P < .001).

CONCLUSION

Anterior humeral head translation and force distribution on the coracoid graft dramatically increased when <100% of the native glenoid width was restored with a Latarjet procedure.

CLINICAL RELEVANCE: If a Latarjet is unable to fully restore the native glenoid width, surgeons should consider alternative graft sources to minimize the risk of recurrent instability or coracoid overload.

Для цитирования: Rauck Ryan C, Brusalis Christopher M, Jahandar Amirhossein, Lamplot Joseph D, Dines David M, Warren Russell F, Gulotta Lawrence V, Kontaxis Andreas, Taylor Samuel A. Complete Restoration of Native Glenoid Width Improves Glenohumeral Biomechanics After Simulated Latarjet.. The American journal of sports medicine. 2023. DOI: 10.1177/03635465231174910.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.