BACKGROUND: Here, we assessed a new trajectory and insertion torque for the placement of a long lateral mass screw (LLMS) that offers stronger posterior fixation versus a shorter lateral mass screw (LMS) in the posterior cervical spine. We report a short technical note of the insertion torque of LLMS.
METHODS: The insertion trajectory/torque was evaluated in 30 patients (10 males and 20 females) undergoing posterior cervical LLMS fusions (2021-2023). Patients averaged 65 years of age. Pathology included eight cervical spine injuries, ten cord injuries, four dislocations/fractures, and eight other entities. Variables studied included the length of the LLMS inserted from C3-7, screw deviation rates, insertion torque, and adverse events.
RESULTS: A total of 146 screws were inserted: 11 pedicle screws (PSs) and 135 LLMS. The average insertion torque was 105.9 cNm for PS and 64.9 cNm for LLMS. As the screw lengthened by 1 mm, the insertion torque increased by approximately 4.4 cNm.
CONCLUSION: Here, we documented that the insertion torque of LLMS was 66.1 cNm, greater than the 51.0 cNm for LMS, which should provide stronger posterior cervical fixation.
METHODS: The insertion trajectory/torque was evaluated in 30 patients (10 males and 20 females) undergoing posterior cervical LLMS fusions (2021-2023). Patients averaged 65 years of age. Pathology included eight cervical spine injuries, ten cord injuries, four dislocations/fractures, and eight other entities. Variables studied included the length of the LLMS inserted from C3-7, screw deviation rates, insertion torque, and adverse events.