DOI 10.1016/j.arth.2010.11.014
Midterm results of 506 solid trispiked reflection cementless acetabular components for primary total hip arthroplasty.
Аннотация
The purpose of this prospective study was to evaluate the outcomes and survivorship of a trispiked, sintered bead-coated titanium shell with a polished inner surface, no screw holes, and an improved locking mechanism. A total of 506 total hip arthroplasties with a minimum 5-year follow-up were available for review at a mean of 7 years (range, 5-11 years). Three sockets (0.6%) were revised for reasons other than aseptic loosening, and 14 (2.8%) polyethylene liners were exchanged. There was no difference in revision rate between non-cross-linked and highly cross-linked liners (P = .4). There were no cases of radiographic loosening. Retroacetabular osteolysis was identified in 2%. The overall 5-year and 10-year Kaplan-Meier survivorship was 97.5% and 97.4%, respectively, whereas survivorship of the shell was 99.8%.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.