MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s00330-016-4711-x

Медицинская библиотека · European radiology · 2017

Extensor tendinopathy of the elbow assessed with sonoelastography: histologic correlation.

Klauser Andrea S, Pamminger Mathias, Halpern Ethan J, Abd Ellah Mohamed M H, Moriggl Bernhard, Taljanovic Mihra S, Deml Christian, Sztankay Judit, Klima Guenther, Jaschke Werner R

Сравнительное исследованиеСтатьяПеревод в очереди

Аннотация

PURPOSE: To compare agreement between conventional B-mode ultrasound (US) and compression sonoelastography (SEL) of the common extensor tendons of the elbow with histological evaluation.

MATERIALS AND

METHODS

Twenty-six common extensor tendons were evaluated in 17 cadavers (11 females, median age 85 years and 6 males, median age 80 years). B-mode US was graded into: Grade 1, homogeneous fibrillar pattern; grade 2, hypoechoic areas and/or calcifications <30%; and grade 3 > 30%. SEL was graded into: Grade 1 indicated blue (hardest) to green (hard); grade 2 yellow (soft); and grade 3 red (softest). B-mode US, SEL, and a combined grading score incorporating both were compared to histological findings in 76 biopsies.

RESULTS

Histological alterations were detected in 55/76 biopsies. Both modalities showed similar results (sensitivity, specificity, and accuracy 84%, 81%, and 83% for B-mode US versus 85%, 86%, and 86% for SEL, respectively, P > 0.3). However, a combination of both resulted in significant improvement in sensitivity (96%, P < 0.02) without significant change in specificity (81%, P < 0.3), yielding an improved overall accuracy (92%).

CONCLUSION

Combined imaging of the extensor tendons with both modalities is superior to either modality alone for predicting the presence of pathologic findings on histology.

KEY POINTS: • Combination of B-mode US and SEL proved efficiency in diagnosing lateral epicondylitis. • Combination of B-mode US and SEL in lateral epicondylitis correlates to histology. • Combination of both modalities provides improved sensitivity without loss of specificity.

Для цитирования: Klauser Andrea S, Pamminger Mathias, Halpern Ethan J, Abd Ellah Mohamed M H, Moriggl Bernhard, Taljanovic Mihra S, Deml Christian, Sztankay Judit, Klima Guenther, Jaschke Werner R. Extensor tendinopathy of the elbow assessed with sonoelastography: histologic correlation.. European radiology. 2017. DOI: 10.1007/s00330-016-4711-x.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.