INTRODUCTION

Treatment of proximal tibial fractures is known to be difficult. We report our own experience of the treatment of these fractures and evaluate our results. The hypothesis was that the clinical and radiological results were good.

MATERIAL AND METHOD: From January 2004 to October 2008, fourteen AO-type 41A2-3 and C1 fractures have been treated with a LCP locking plate (8 women and 6 men, average age 60.42). Plating was performed either with an open approach or a minimal invasive approach. Clinical and radiological follow-up was carried out looking for range of motion of the knee joint and autonomy level.

RESULTS

Mean follow-up was 32.63 months (12-70). Range of motion was maintained with a mean arch of 117.5° Autonomy was maintained in all cases. Professional, domestic and sports activities were unchanged. No infection or general complication occurred. Bone fusion was obtained in all cases after an average of 13.28 weeks. 6° of valgus deformation, already seen immediately postoperatively was observed once. Secondary displacement was observed in 6 cases, with an average of 2.83° DISCUSSION-

CONCLUSION

We report good radiological results, with only one initial malalignment. The hypothesis was confirmed. However, X-ray analysis at consolidation shows 6 secondary displacements, without any satisfactory explanation. Though the clinical consequences of these malunions are minimal. Osteosynthesis with plate, in the sight of this study, yields good clinical results. Radiological evolution concerning the evolution of bone axes puts the emphasis on careful operative technique and adequate time to weight bearing.

LEVEL OF EVIDENCE: retrospective study, IV.

Для цитирования: Favreau Henri, Tamir Mekki, Adam Philippe, Ollivier Matthieu, Bonnomet François, Ehlinger Matthieu. Osteosynthesis by locking plate for proximal tibial fractures.. Injury. 2024. DOI: 10.1016/j.injury.2024.111407.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.