MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1111/ijlh.12422

Медицинская библиотека · International journal of laboratory hematology · 2015

New parameters available on Sysmex XE-5000 hematology analyzers contribute to differentiating dengue from leptospirosis and enteric fever.

Oehadian A, Michels M, de Mast Q, Prihatni D, Puspita M, Hartantri Y, Sinarta S, van der Ven A J A M, Alisjahbana B

СтатьяПеревод в очереди

Аннотация

INTRODUCTION

Distinguishing dengue virus infection from other febrile thrombocytopenic illnesses such as leptospirosis or enteric fever is important but difficult, due to the unavailability of reliable diagnostic tests. Sysmex XE-5000 hematology analyzers use fluorescence flow cytometry to quantitate new parameters including cells in the atypical lymphocyte area (AL), high-fluorescent lymphocyte counts (HFLC), immature granulocytes (IG), and immature platelets (IPF). This study aimed to investigate whether these parameters can help to discriminate between the diseases.

MATERIAL AND

METHODS

We compared hematocytometry performed by a Sysmex XE-5000 analyzer in Indonesian adults with dengue (n = 93), leptospirosis (n = 11), and enteric fever (n = 6) infection, and in healthy controls (n = 28).

RESULTS

Receiver operating characteristic curves comparing dengue and leptospirosis showed that dengue was characterized by increased %AL (AUC 0.87; 95% CI 0.70-1.03), %HFLC (AUC 0.89; 95% CI 0.78-0.99), and %IPF (AUC 0.81; 95% CI 0.65-0.97), while patients with leptospirosis had increased %IG (AUC 0.86; 95% CI 0.71-1.02). Low %AL, %HFLC, and %IG supported a diagnosis of enteric fever.

CONCLUSIONS

The detection of AL, HFLC, IG, and IPF by Sysmex XE-5000 hematology analyzers can help to differentiate between common causes of febrile illnesses with thrombocytopenia in dengue endemic areas. We recommend further investigating the discriminatory value of these parameters in clinical practice.

Для цитирования: Oehadian A, Michels M, de Mast Q, Prihatni D, Puspita M, Hartantri Y, Sinarta S, van der Ven A J A M, Alisjahbana B. New parameters available on Sysmex XE-5000 hematology analyzers contribute to differentiating dengue from leptospirosis and enteric fever.. International journal of laboratory hematology. 2015. DOI: 10.1111/ijlh.12422.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.