m+Medelevator.RU
← Поиск публикаций
The bone & joint journal · 2026

Robotic-assisted surgery and functional alignment in total knee arthroplasty: the RASKAL registry-nested 2 × 2 factorial randomized trial.

СтатьяРандомизированное исследованиеМногоцентровое исследованиеНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

MacDessi Samuel J, Wernecke Gregory C, Ghadirinejad Khashayar, Wood Jil A, Holder Carl, Lorimer Michelle, Harris Ian A, and the RASKAL Study Group, Bastiras Durga, Boyle Richard, Chen Darren B, Du Peiyao, Fritsch Brett, Guzman Maurice, Kirsh George, Leong Anthony, Limbers John, McEwen Peter, McMahon Stephen, Mulford Jonathan, Oakey Helena, Penn David, Yu Julian

Аннотация

AIMS: Robotic-assisted surgery and functional alignment are increasingly being adopted in total knee arthroplasty (TKA). This study assessed the individual and combined effectiveness of robotic-assisted surgery and functional alignment in improving outcomes in TKA, compared with computer-assisted surgery and mechanical alignment, respectively.

METHODS: A registry-nested, multicentre, blinded, 2 × 2 factorial, randomized trial was performed with 303 TKA patients randomized to robotic-assisted or computer-assisted surgery, and functional or mechanical alignment. The primary outcome was the between-group differences in postoperative change over two years in the mean Knee Injury and Osteoarthritis Outcome Score (KOOS-12). Secondary outcomes included knee-specific and general patient-reported outcome measures (PROMs), operative and functional outcomes, and adverse events. Primary modified intention-to-treat and secondary per-protocol analyses were performed.

RESULTS: There were no differences comparing robotic-assisted with computer-assisted surgery in KOOS-12 at three months, six months, one year, and two years (mean two-year difference -2.8; 95% CI -6.4 to 0.9; p = 0.137), and no differences comparing functional with mechanical alignment at three months, six months, one year, and two years (mean two-year difference 0.3 (95% CI -3.4 to 4.0); p = 0.867). No differences were found in Oxford Knee Score, Forgotten Joint Score, EuroQol five-dimension five-level visual analogue scale, patient satisfaction, joint-related improvement, and pain comparing technology or alignment groups at three months, six months, one year, and two years. Robotic-assisted surgery had a shorter mean operating time by 11.5 minutes (95% CI 7.3 to 15.9; p < 0.001) and better mean posterior cruciate ligament macroscopic soft-tissue injury score (mean difference 0.7 (95% CI 0.3 to 1.1); p = 0.001) compared with computer-assisted surgery. Mechanical alignment had a higher soft-tissue release rate compared with functional alignment (44.8% vs 8.1%; OR 9.2 (95% CI 4.6 to 18.3); p < 0.001). In most cases, surgeons preferred the use of robotics and functional alignment.

CONCLUSION: Robotic-assisted surgery and functional alignment were not superior to computer-assisted surgery and mechanical alignment, respectively, in improving clinical and functional outcomes up to two years post-TKA.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты