MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1002/jeo2.12106

Медицинская библиотека · Journal of experimental orthopaedics · 2024

Vitamin E-stabilized polyethylene shows similar survival rates at minimum 7-year follow-up compared to conventional polyethylene in primary total knee arthroplasty.

Bistolfi Alessandro, Spezia Marco, Cipolla Alessandra, Bonera Monica, Mellano Danilo, Banci Lorenzo, Colombo Marta, Massè Alessandro

СтатьяПеревод в очереди

Аннотация

PURPOSE: The aim of this cross-sectional study was to compare survival, clinical and radiographic results of total knee arthroplasty (TKA) with vitamin E-stabilized polyethylene (VEPE) or conventional polyethylene (CPE) at a minimum of 7-year follow-up.

METHODS

Patients who underwent primary TKA between 2011 and 2015, receiving the same cemented rotating platform knee design with VEPE or CPE tibial inserts, were identified. Patients were contacted for clinical and radiographic follow-up. American Knee Society Score (KSS), Forgotten Joint Score (FJS-12), presence of periprosthetic radiolucent lines (RLLs) and osteolysis were evaluated at the last follow-up. Any revision, reintervention or other complications were recorded.

RESULTS

Among 350 TKAs initially identified, 102 VEPE and 97 CPE knees were included for analysis with mean follow-up of 8.5 and 8.3 years, respectively. No significant difference was found in survival rates at 10-year follow-up with revision due to aseptic loosening (95.0% vs. 97.8%, p = 0.29) or due to any reason (87.6% vs. 89.6%, p = 0.78) between VEPE and CPE TKA. KSS function score resulted significantly higher in the VEPE group over CPE (77 vs. 63, p = 0.01). RLLs were more frequent in VEPE than CPE (54% vs. 32%, p = 0.05), mainly noticed medially and posteriorly beneath the tibial plate, adjacent to the trochlear shield and the posterior condyles. Osteolysis was observed in one knee per group, but patients were asymptomatic with stable implants.

CONCLUSION

TKA with VEPE and CPE tibial inserts showed comparable survival rates, complications and clinical and radiographic results up to 10-year follow-up.

LEVEL OF EVIDENCE: Level III.

Для цитирования: Bistolfi Alessandro, Spezia Marco, Cipolla Alessandra, Bonera Monica, Mellano Danilo, Banci Lorenzo, Colombo Marta, Massè Alessandro. Vitamin E-stabilized polyethylene shows similar survival rates at minimum 7-year follow-up compared to conventional polyethylene in primary total knee arthroplasty.. Journal of experimental orthopaedics. 2024. DOI: 10.1002/jeo2.12106.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.