A New MRI Grading System for Cervical Foraminal Stenosis Based on Axial T2-Weighted Images.

Kim Sujin, Lee Joon Woo, Chai Jee Won, Yoo Hye Jin, Kang Yusuhn, Seo Jiwoon, Ahn Joong Mo, Kang Heung Sik

СтатьяПеревод в очереди

Аннотация

OBJECTIVE

The purpose of this study was to evaluate the reliability of a new magnetic resonance imaging (MRI) grading system for cervical neural foraminal stenosis (NFS).

MATERIALS AND

METHODS

Cervical NFS at bilateral C4/5, C5/6, and C6/7 was classified into the following three grades based on the T2-weighted axial images: Grade 0 = absence of NFS, with the narrowest width of the neural foramen greater than the width of the extraforaminal nerve root (EFNR); Grade 1 = the narrowest width of the neural foramen the same or less than (but more than 50% of) the width of the EFNR; Grade 2 = the width of the neural foramen the same or less than 50% of the width of the EFNR. The MRIs of 96 patients who were over 60 years old (M:F = 50:46; mean age 68.4 years; range 61-86 years) were independently analyzed by seven radiologists. Interobserver and intraobserver agreements were analyzed using the percentage agreement, kappa statistics, and intraclass correlation coefficient (ICC).

RESULTS

For the distinction among the three individual grades at all six neural foramina, the ICC ranged from 0.68 to 0.73, indicating fair to good reproducibility. The percentage agreement ranged from 60.2% to 70.6%, and the kappa values (κ = 0.50-0.58) indicated fair to moderate agreement. The percentages of intraobserver agreement ranged from 85.4% to 93.8% (κ = 0.80-0.92), indicating near perfect agreement.

CONCLUSION

The new MRI grading system shows sufficient interobserver and intraobserver agreement to reliably assess cervical NFS.

Для цитирования: Kim Sujin, Lee Joon Woo, Chai Jee Won, Yoo Hye Jin, Kang Yusuhn, Seo Jiwoon, Ahn Joong Mo, Kang Heung Sik. A New MRI Grading System for Cervical Foraminal Stenosis Based on Axial T2-Weighted Images.. Korean journal of radiology. 2015. DOI: 10.3348/kjr.2015.16.6.1294.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.