High Rates of Early Septic Failure, but Low Rates of Aseptic Loosening After Revision Total Knee Arthroplasty With Contemporary Rotating-Hinge Prostheses.

Bornes Troy D, Puri Simarjeet, Neitzke Colin C, Chandi Sonia K, Gausden Elizabeth B, Sculco Peter K, Chalmers Brian P

СтатьяПеревод в очереди

Аннотация

BACKGROUND

The purpose of this study was to determine implant survivorship and functional outcomes for revision total knee arthroplasty (rTKA) with contemporary rotating-hinge knee implants.

METHODS

A retrospective review identified 115 rTKAs using contemporary rotating-hinge implants from 2014 to 2018 for the treatment of instability (34, 30%), reimplantation after periprosthetic joint infection (PJI) (33, 29%), aseptic loosening (25, 22%), arthrofibrosis (14, 12%), periprosthetic fracture (4, 3%), osteolysis (4, 3%), and femoral component fracture (1, 1%). There were 70 women (61%), and the mean age was 67 years (range, 27 to 94). The mean follow-up was 3 years (range, 2 to 6). Kaplan-Meier analysis and Cox proportional hazard models estimated survivorship.

RESULTS

The re-revision rate was 20% (23 of 115) at an average of 18 months postoperatively. Re-revision indications included PJI (n = 14), aseptic loosening (n = 4), arthrofibrosis (n = 2), instability/malalignment (n = 1), femoral stem fracture (n = 1), and hinge mechanism disruption (n = 1). At 2 and 5 years, survivorship free from all-cause re-revision was 86 and 64%, and survivorship free from re-revision for aseptic loosening was 100 and 87%, respectively. Use of a rotating-hinge implant in reimplantation after PJI was a risk factor for subsequent re-revision (hazard ratio = 2.4, P = 0.046). On a radiographic review of unrevised rotating-hinges, there were major radiolucent lines around 2 femoral and 5 tibial components. The mean Knee Injury and Osteoarthritis Outcomes Score for Joint Replacement increased from 43 preoperatively to 60 at 1 year (P < 0.001).

CONCLUSIONS

In patients treated with a rotating-hinge implant for rTKA, there were relatively poor 2-year (86%) and 5-year (64%) survivorship free from all-cause re-revision, most commonly due to PJI. Midterm survivorship free from re-revision for aseptic loosening was modest (87%). There should be a goal to mitigate complications in complex rTKAs with rotating-hinge implants, namely PJI.

Для цитирования: Bornes Troy D, Puri Simarjeet, Neitzke Colin C, Chandi Sonia K, Gausden Elizabeth B, Sculco Peter K, Chalmers Brian P. High Rates of Early Septic Failure, but Low Rates of Aseptic Loosening After Revision Total Knee Arthroplasty With Contemporary Rotating-Hinge Prostheses.. The Journal of arthroplasty. 2024. DOI: 10.1016/j.arth.2024.08.013.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.