Hand (New York, N.Y.) · 2024
Biomechanical Comparison of FiberLock Suspensionplasty and Flexor Carpi Radialis Ligament Reconstruction for Treatment of Thumb Carpometacarpal Osteoarthritis.
СтатьяСравнительное исследованиеНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Nakla Andrew P, Shin Steven S, Kwak Daniel, Chung Min-Shik, McGarry Michelle H, Lee Thay Q
Аннотация
BACKGROUND: The purpose of this study was to compare the cyclic and load to failure characteristics of post-trapeziectomy suspensionplasty with the FiberLock Suspension System (FLSS; Arthrex Inc., Naples, Florida) to flexor carpi radialis ligament reconstruction (FCRLR). We hypothesized that the FLSS will have increased stiffness, yield, and ultimate load compared with FCRLR.
METHODS: Ten matched pairs of cadaveric hands were used. One side of each pair was randomly assigned to receive the FCRLR or FLSS and the contralateral side received the other suspensionplasty. A complete trapeziectomy was performed followed by FLSS or FCRLR. Cyclic and load to failure characteristics were measured with loading in the distal to proximal direction. A preload of 1 N with 30 cycles of 1 N to 10 N was applied, followed by load to failure. A paired t test was used for statistical analysis (P < .05).
RESULTS: The FLSS had significantly decreased nonrecoverable deformation and deformation at peak load during cyclic loading (P < .04). The FLSS also had significantly increased stiffness, yield load, ultimate load, and load and energy absorbed at 10 mm displacement compared with FCRLR (P < .04). All 10 FCRLR specimens failed with suture tearing through the tendon. Nine FLSS specimens failed due to suture slipping from the SwiveLock anchor (Arthrex Inc., Naples, Florida) and 1 failed due to the FiberTak anchor (Arthrex Inc., Naples, Florida) pulling through the index metacarpal.
CONCLUSION: Suspensionplasty with the FLSS demonstrated greater structural integrity compared with FCRLR following trapeziectomy. The FLSS procedure may result in decreased thumb subsidence and decreased construct failure.
METHODS: Ten matched pairs of cadaveric hands were used. One side of each pair was randomly assigned to receive the FCRLR or FLSS and the contralateral side received the other suspensionplasty. A complete trapeziectomy was performed followed by FLSS or FCRLR. Cyclic and load to failure characteristics were measured with loading in the distal to proximal direction. A preload of 1 N with 30 cycles of 1 N to 10 N was applied, followed by load to failure. A paired t test was used for statistical analysis (P < .05).
RESULTS: The FLSS had significantly decreased nonrecoverable deformation and deformation at peak load during cyclic loading (P < .04). The FLSS also had significantly increased stiffness, yield load, ultimate load, and load and energy absorbed at 10 mm displacement compared with FCRLR (P < .04). All 10 FCRLR specimens failed with suture tearing through the tendon. Nine FLSS specimens failed due to suture slipping from the SwiveLock anchor (Arthrex Inc., Naples, Florida) and 1 failed due to the FiberTak anchor (Arthrex Inc., Naples, Florida) pulling through the index metacarpal.
CONCLUSION: Suspensionplasty with the FLSS demonstrated greater structural integrity compared with FCRLR following trapeziectomy. The FLSS procedure may result in decreased thumb subsidence and decreased construct failure.