DOI 10.1097/bpo.0000000000002668
Is Using a Ring External Fixator in the Treatment of Congenital Pseudarthrosis of the Tibia Associated With Better Results or Using a Locking Plate?
Аннотация
BACKGROUND
Congenital pseudarthrosis of the tibia (CPT) is a rare disease. CPT is often unilateral and occurs between the middle and distal third of the tibia. Concurrent involvement of the fibula is present in more than half of cases. histologic studies indicate the presence of fibrous hamartoma tissue and a sick periosteum, which leads to recalcitrant bone fracture and, eventually, pseudoarthrosis. Although there are various surgical techniques, we intend to compare the 2 methods of external fixation versus internal plating.
METHODS
Demographic data were collected from 26 patients with frank pseudoarthrosis. After exclusion criteria, patients were compared in groups A (12 patients) and B (11 patients). Resection of hamartoma and sclerotic bone, intramedullary rodding and autologous bone, and periosteal grafting were performed for all patients. In group A, we used a ring external fixator for compression and rotational stability, but in group B, a locking plate was used for these purposes.
RESULTS
Plating takes less time to use during surgery. In group A, the primary bony union was obtained in 67% of patients, while in group B, 82% of patients had a primary union. Meanwhile, the average time till the final union in group A was 6 months, while in group B, this time was 3.5 months. Positive union mass was obtained in 58% of the patients in group A and 82% of group B. In addition, plating prevented ankle valgus deformity in group B.
CONCLUSIONS
Permanent intramedullary rodding is a surgical requirement for correction of deformity and refracture prevention, but additional stability can be achieved with the use of a ring external fixator or internal plate. Cross union and positive union mass are 2 important factors in the treatment of pseudoarthrosis; these results are achieved to a greater extent and in a shorter period of time using the plate.
LEVEL OF EVIDENCE: level IV - case series.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.