Analytical and Clinical Validation of a Remote Laboratory Test for Prothrombin Time and INR Determination in Patients with Antiphospholipid Antibody Syndrome and Systemic Lupus Erythematosus.

СтатьяНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Jantzch Gabriela Victória de Mello, Bernasconi Rodrigo Ritzel, Souza Milleny Germann, Moraes Duane da Silva, Serafini Bruna Ferri, Dos Santos Leonardo Peterson, Moreira Julia Konzen, Xavier Ricardo Machado

Аннотация

Antiphospholipid syndrome (APS) is an autoimmune disorder associated with antiphospholipid antibodies, leading to coagulation imbalance, thrombosis, and obstetric complications. It may occur as a primary condition or in association with systemic lupus erythematosus (SLE). Patients with APS often require long-term anticoagulation therapy, monitored by prothrombin time (PT) expressed as international normalized ratio (INR). Remote laboratory testing (RLT) devices may improve monitoring by providing faster and more convenient results; however, their accuracy in APS patients remains uncertain. This study aimed to validate a rapid and portable device (bSens.INR) for PT/INR measurement in patients with APS and SLE receiving warfarin, compared to a control group without these conditions. Accuracy, repeatability, and agreement with the standard laboratory method were evaluated according to established guidelines. A total of 40 PT/INR measurements were obtained using the bSens.INR and 20 using the standard method. Overall concordance was 77.5%, with lower agreement in APS/SLE patients (60%) compared to controls (95%). Approved results showed 100% repeatability. A strong positive correlation was observed between methods (Spearman r = 0.80, p < 0.0001), while Bland-Altman analysis indicated a bias of 0.26 INR units. The presence of antiphospholipid antibodies appears to interfere with PT/INR measurements obtained by the bSens.INR, reducing accuracy in APS and SLE patients. Although the device shows promising performance, its use in autoimmune populations should be approached with caution, reinforcing previous findings on the limitations of RLT in these conditions.

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты