DOI 10.1007/s00586-023-07689-2
A retrospective review of single-position prone lateral lumbar interbody fusion cases: early learning curve and perioperative outcomes.
Аннотация
PURPOSE: The objective of this study was to discuss our experience performing LLIF in the prone position and report our complications.
METHODS
A retrospective chart review was conducted that included all patients who underwent single- or multi-level single-position pLLIF alone or as part of a concomitant procedure by the same surgeon from May 2019 to November 2022.
RESULTS
A total of 155 patients and 250 levels were included in this study. Surgery was most commonly performed at the L4-L5 level (n = 100, 40%). The most common preoperative diagnosis was spondylolisthesis (n = 74, 47.7%). In the first 30 cases, 3 surgeries were aborted to an MIS TLIF. Complications included 3 unintentional ALL ruptures (n = 3/250, 1.2%), and 1 malpositioned implant impinging on the contralateral foramen requiring revision (n = 1/250, 0.4%), which all occurred within the first 30 cases. Out of 147 patients with more than 6-week follow-ups, there were 3 cases of femoral nerve palsy (n = 3/147, 2.0%). Two cases of femoral nerve palsy improved to preoperative strength by the 6th week postoperatively, while one improved to 4/5 preoperative strength by 1 year. There were no cases of bowel perforation or vascular injury.
CONCLUSION
Our single-surgeon experience demonstrates the initial learning curve when adopting pLLIF. Thereafter, we experienced reproducibility in our technique and large improvements in our operative times, and complication profile. We experienced no technical complications after the 30th case. Further studies will include long-term clinical and radiographic outcomes to understand the complete utility of this approach.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.