MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1055/s-0034-1382785

Медицинская библиотека · Journal of neurological surgery. Part A, Central European neurosurgery · 2015

Comparative Analysis of Inpatient and Outpatient Interspinous Process Device Placement for Lumbar Spinal Stenosis.

Ortega Alicia, Sarmiento J Manuel, Patil Chirag, Mukherjee Debraj, Ugiliweneza Beatrice, Nuño Miriam, Lad Shivanand, Boakye Maxwell

Сравнительное исследованиеСтатьяПеревод в очереди

Аннотация

PURPOSE: To compare reoperations, health care utilization, and costs in lumbar spinal stenosis (LSS) patients undergoing interspinous process (ISP) device placement in an inpatient versus outpatient setting.

METHODS

The MarketScan database (2007-2009) was queried for adults with LSS undergoing ISP device placement as a primary procedure. Reoperations, health care utilization, and costs in patients with at least 18 months of follow-up were analyzed. Chi-square and Student t tests were used to assess the differences in characteristics and outcomes between patients treated in the inpatient and outpatient setting.

RESULTS

A total of 411 patients who underwent ISP device placement were identified; the mean age was 72 years, 51% were female, and most patients were insured by Medicare (73.7%). The average postoperative follow-up was 24.9 months. A subset of 182 patients (44.3%) had inpatient procedures; 229 (55.7%) underwent outpatient ISP device placements. The overall reoperation rate was 20.4%. ISP reoperation rates between inpatient and outpatient cohorts were comparable (23.1% versus 18.3%; p = 0.24). Inpatients accrued significantly higher index procedural costs compared with outpatients ($17,432 versus $8854; p = 0.0001), however, the outpatient cohort utilized more postoperative outpatient services (143 versus 112; p = 0.09) and higher outpatient service costs ($25,376 versus $15,481; p = 0.01). Consequently, cumulative overall cost was similar among the two cohorts ($51,059 versus $51,778; p = 0.94).

CONCLUSIONS

Long-term reoperation rates following ISP device placement are comparable in the inpatient and outpatient setting. Upfront cost savings may be achieved with outpatient ISP device placement, but this benefit is lost by 18 months following initial surgery.

Для цитирования: Ortega Alicia, Sarmiento J Manuel, Patil Chirag, Mukherjee Debraj, Ugiliweneza Beatrice, Nuño Miriam, Lad Shivanand, Boakye Maxwell. Comparative Analysis of Inpatient and Outpatient Interspinous Process Device Placement for Lumbar Spinal Stenosis.. Journal of neurological surgery. Part A, Central European neurosurgery. 2015. DOI: 10.1055/s-0034-1382785.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.