Larger Real-World OCT Reference Database Improves Accuracy of Glaucoma Flagging Using Summary Metrics.

Hood Donald C, Durbin Mary, Lee Chris, Guzman Anya, Gebhardt Tayna, Wang Yujia, De Moraes Carlos Gustavo, Tsamis Emmanouil

СтатьяПеревод в очереди

Аннотация

PURPOSE: To compare the healthy control and glaucoma eyes flagged as outside normal limits (yellow or red) by a commercial reference database (C-RDB) and a larger real-world (RW)-RDB.

METHODS

The C-RDB consisted of 398 eyes/individuals. Based only on optical coherence tomography (OCT) reports, the RW-RDB consisted of 4830 eyes/individuals selected from optometry practices using a reading center method. The fifth and first percentile quantile regression lines (QRLs) versus age were calculated for both RDBs for common OCT metrics, including global circumpapillary retinal nerve fiber (g-cpRNFL) and global ganglion cell layer plus inner plexiform layer (g-GCL+) thickness. The test dataset contained 175 healthy control (H) eyes and 183 eyes with OCT defects consistent with optic neuropathy-glaucoma (ON-G). These eyes were flagged as yellow (red) if they fell below the fifth (first) percentile QRL. The QRLs were also compared to a Gaussian model and Monte Carlo simulations.

RESULTS

The C-RDB and RW-RDB did not flag an identical set of eyes as red or yellow. In fact, 16% (g-cpRNFL) and 7% (g-GCL+) of the 183 ON-G eyes had a different color flag. The results of the model and simulations support the hypothesis that both RDBs are sampled from essentially the same underlying "normal" population. Thus, the difference between them is largely due to less random error in the larger sample.

CONCLUSIONS

There is a difference in the eyes flagged, and this difference is largely due to the greater size of the RW-RDB.

TRANSLATIONAL RELEVANCE: These findings support the clinical value of expanding reference databases to improve diagnostic accuracy of glaucoma flagging.

Для цитирования: Hood Donald C, Durbin Mary, Lee Chris, Guzman Anya, Gebhardt Tayna, Wang Yujia, De Moraes Carlos Gustavo, Tsamis Emmanouil. Larger Real-World OCT Reference Database Improves Accuracy of Glaucoma Flagging Using Summary Metrics.. Translational vision science & technology. 2026. DOI: 10.1167/tvst.15.3.6.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.