MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1038/s41598-022-23863-w

Медицинская библиотека · Scientific reports · 2022

Evaluation of U-Net models in automated cervical spine and cranial bone segmentation using X-ray images for traumatic atlanto-occipital dislocation diagnosis.

Shim Jae-Hyuk, Kim Woo Seok, Kim Kwang Gi, Yee Gi Taek, Kim Young Jae, Jeong Tae Seok

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

Segmentation of the cervical spine in tandem with three cranial bones, hard palate, basion, and opisthion using X-ray images is crucial for measuring metrics used to diagnose traumatic atlanto-occipital dislocation (TAOD). Previous studies utilizing automated segmentation methods have been limited to segmenting parts of the cervical spine (C3 ~ C7), due to difficulties in defining the boundaries of C1 and C2 bones. Additionally, there has yet to be a study that includes cranial bone segmentations necessary for determining TAOD diagnosing metrics, which are usually defined by measuring the distance between certain cervical (C1 ~ C7) and cranial (hard palate, basion, opisthion) bones. For this study, we trained a U-Net model on 513 sagittal X-ray images with segmentations of both cervical and cranial bones for an automated solution to segmenting important features for diagnosing TAOD. Additionally, we tested U-Net derivatives, recurrent residual U-Net, attention U-Net, and attention recurrent residual U-Net to observe any notable differences in segmentation behavior. The accuracy of U-Net models ranged from 99.07 to 99.12%, and dice coefficient values ranged from 88.55 to 89.41%. Results showed that all 4 tested U-Net models were capable of segmenting bones used in measuring TAOD metrics with high accuracy.

Для цитирования: Shim Jae-Hyuk, Kim Woo Seok, Kim Kwang Gi, Yee Gi Taek, Kim Young Jae, Jeong Tae Seok. Evaluation of U-Net models in automated cervical spine and cranial bone segmentation using X-ray images for traumatic atlanto-occipital dislocation diagnosis.. Scientific reports. 2022. DOI: 10.1038/s41598-022-23863-w.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.