MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1186/s12891-025-09268-6

Медицинская библиотека · BMC musculoskeletal disorders · 2025

Odontoid base hypodensity and its role in type II fracture risk and nonunion: a CT study.

Dong Wei-Xin, Ma Weihu, Xu Nanjian, Hu Yong

СтатьяПеревод в очереди

Аннотация

BACKGROUND

Type II odontoid fractures show high incidence and a notable risk of nonunion. Whether regional variation in trabecular density at the odontoid base contributes to this vulnerability remains unclear.

METHODS

We retrospectively analyzed cervical CT scans from 136 adults. Standardized oval regions of interest (ROIs) were placed within cancellous bone while avoiding cortex and sclerosis. Mean Hounsfield unit (HU) values were compared across three predefined regions-the odontoid tip, odontoid base, and C2 vertebral body-with age- and sex-stratified analyses using analysis of variance and multiple-comparison adjustment. Two blinded observers performed the measurements, and reproducibility was quantified with intraclass correlation coefficients (ICCs).

RESULTS

HU values were highest at the odontoid tip, lowest at the base, and intermediate at the C2 body. On average, HU declined by ~ 51% from tip to base and then partially increased at the body. This regional pattern persisted across age and sex strata, and older individuals showed lower base HU. All primary regional comparisons remained statistically significant after adjustment.

CONCLUSIONS

The odontoid base appears to be a structurally vulnerable zone with reduced trabecular density. This hypodensity may help explain the high incidence and may be associated with nonunion of type II odontoid fractures, particularly in elderly patients; however, biomechanical and clinical studies are required before informing definitive treatment recommendations.

Для цитирования: Dong Wei-Xin, Ma Weihu, Xu Nanjian, Hu Yong. Odontoid base hypodensity and its role in type II fracture risk and nonunion: a CT study.. BMC musculoskeletal disorders. 2025. DOI: 10.1186/s12891-025-09268-6.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.