The spine journal : official journal of the North American Spine Society · 2023
An investigational time course study of titanium plasma spray on osseointegration of PEEK and titanium implants: an in vivo ovine model.
СтатьяНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Cunningham Bryan W, Brooks Daina M, Rolle Nicholas P, Weiner David A, Wang Wenhai
Аннотация
BACKGROUND CONTEXT: Methods to improve osseointegration of orthopedic spinal implants remains a clinical challenge. Materials composed of poly-ether-ether-ketone (PEEK) and titanium are commonly used in orthopedic applications due to their inherent properties of biocompatibility. Titanium has a clinical reputation for durability and osseous affinity, and PEEK offers advantages of a modulus that approximates osseous structures and is radiolucent. The hypothesis for the current investigation was that a titanium plasma spray (TPS) coating may increase the rate and magnitude of circumferential and appositional trabecular osseointegration of PEEK and titanium implants versus uncoated controls.
PURPOSE: Using an in vivo ovine model, the current investigation compared titanium plasma-sprayed PEEK and titanium dowels versus nonplasma-sprayed dowels. Using a time course study of 6 and 12 weeks postoperatively, experimental assays to quantify osseointegration included micro-computed tomography (microCT), biomechanical testing, and histomorphometry.
STUDY DESIGN/SETTING: In-vivo ovine model.
METHODS: Twelve skeletally mature crossbred sheep were equally randomized into postoperative periods of 6 and 12 weeks. Four types of dowel implants-PEEK, titanium plasma-sprayed PEEK (TPS PEEK), titanium, and titanium plasma-sprayed titanium (TPS titanium) were implanted into cylindrical metaphyseal defects in the distal femurs and proximal humeri (one defect per limb, n=48 sites). Sixteen nonoperative specimens (eight femurs and eight humeri) served as zero time-point controls. Half of the specimens underwent destructive biomechanical pullout testing and the remaining half quantitative microCT to quantify circumferential bone volume within 1 mm and 2 mm of the implant surface and histomorphometry to compute direct trabecular apposition.
RESULTS: There were no intra- or perioperative complications. The TPS-coated implants demonstrated significantly higher peak loads at dowel pullout at 6 and 12 weeks compared with uncoated controls (p<.05). No differences were observed across dowel treatments at the zero time-point (p>.05). MicroCT results exhibited no significant differences in circumferential osseointegration between implants within 1 mm or 2 mm of the dowel surface (p>.05). Direct appositional osseointegration of trabecular bone based on histomorphometry was higher for TPS-coated groups, regardless of base material, compared with uncoated treatments at both time intervals (p<.05).
CONCLUSIONS: The current in vivo study demonstrated the biological and mechanical advantages of plasma spray coatings. TPS improved histological incorporation and peak force required for implant extraction.
CLINICAL SIGNIFICANCE: Plasma spray coatings may offer clinical benefit by improving biological fixation and osseointegration within the first 6 to 12 weeks postoperatively- the critical healing period for implant-based arthrodesis procedures.
PURPOSE: Using an in vivo ovine model, the current investigation compared titanium plasma-sprayed PEEK and titanium dowels versus nonplasma-sprayed dowels. Using a time course study of 6 and 12 weeks postoperatively, experimental assays to quantify osseointegration included micro-computed tomography (microCT), biomechanical testing, and histomorphometry.
STUDY DESIGN/SETTING: In-vivo ovine model.
METHODS: Twelve skeletally mature crossbred sheep were equally randomized into postoperative periods of 6 and 12 weeks. Four types of dowel implants-PEEK, titanium plasma-sprayed PEEK (TPS PEEK), titanium, and titanium plasma-sprayed titanium (TPS titanium) were implanted into cylindrical metaphyseal defects in the distal femurs and proximal humeri (one defect per limb, n=48 sites). Sixteen nonoperative specimens (eight femurs and eight humeri) served as zero time-point controls. Half of the specimens underwent destructive biomechanical pullout testing and the remaining half quantitative microCT to quantify circumferential bone volume within 1 mm and 2 mm of the implant surface and histomorphometry to compute direct trabecular apposition.
RESULTS: There were no intra- or perioperative complications. The TPS-coated implants demonstrated significantly higher peak loads at dowel pullout at 6 and 12 weeks compared with uncoated controls (p<.05). No differences were observed across dowel treatments at the zero time-point (p>.05). MicroCT results exhibited no significant differences in circumferential osseointegration between implants within 1 mm or 2 mm of the dowel surface (p>.05). Direct appositional osseointegration of trabecular bone based on histomorphometry was higher for TPS-coated groups, regardless of base material, compared with uncoated treatments at both time intervals (p<.05).
CONCLUSIONS: The current in vivo study demonstrated the biological and mechanical advantages of plasma spray coatings. TPS improved histological incorporation and peak force required for implant extraction.
CLINICAL SIGNIFICANCE: Plasma spray coatings may offer clinical benefit by improving biological fixation and osseointegration within the first 6 to 12 weeks postoperatively- the critical healing period for implant-based arthrodesis procedures.