DOI 10.7507/1002-1892.202306071
[Clinical application of percutaneous pedicle screw placement guided by ultrasound volume navigation combined with X-ray fluoroscopy: a prospective randomized controlled study].
Аннотация
OBJECTIVE
To explore the feasibility and accuracy of ultrasound volume navigation (UVN) combined with X-ray fluoroscopy-guided percutaneous pedicle screw implantation through a prospective randomized controlled study.
METHODS
Patients with thoracic and lumbar vertebral fractures scheduled for percutaneous pedicle screw fixation between January 2022 and January 2023 were enrolled. Among them, 60 patients met the selection criteria and were included in the study. There were 28 males and 32 females, with an average age of 49.5 years (range, 29-60 years). The cause of injury included 20 cases of traffic accidents, 21 cases of falls, 17 cases of slips, and 2 cases of heavy object impact. The interval from injury to hospital admission ranged from 1 to 5 days (mean, 1.57 days). The fracture located at T 12 in 15 cases, L 1 in 20 cases, L 2 in 19 cases, and L 3 in 6 cases. The study used each patient as their own control, randomly guiding pedicle screw implantation using UVN combined with X-ray fluoroscopy on one side of the vertebral body and the adjacent segment (trial group), while the other side was implanted under X-ray fluoroscopy (control group). A total of 4 screws and 2 rods were implanted in each patient. The implantation time and fluoroscopy frequency during implantation of each screw, angle deviation and distance deviation between actual and preoperative planned trajectory by imaging examination, and the occurrence of zygapophysial joint invasion were recorded.
RESULTS
In terms of screw implantation time, fluoroscopy frequency, angle deviation, distance deviation, and incidence of zygapophysial joint invasion, the trial group showed superior results compared to the control group, and the differences were significant ( P<0.05).
CONCLUSION
UVN combined with X-ray fluoroscopy-guided percutaneous pedicle screw implantation can yreduce screw implantation time, adjust dynamically, reduce operational difficulty, and reduce radiation damage.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.