Медицинская библиотека · Hand surgery : an international journal devoted to hand and upper limb surgery and related research : journal of the Asia-Pacific Federation of Societies for Surgery of the Hand · 2014

Reliability of the Hand20 questionnaire: comparison with the 36-Item Short-Form Health Survey.

Moritomo Hisao, Imaeda Toshihiko, Gotani Hiroyuki, Momose Toshimitsu, Abe Yukio, Oi Hiroyuki, Omokawa Shohei, Sawaizumi Takuya, Nemoto Koichi, Functional Evaluation Committee of Japanese Society for Surgery of Hand

Сравнительное исследованиеСтатьяПоддержка исследования: вне правительства СШАВалидационное исследованиеПеревод в очереди

Аннотация

BACKGROUND

Hand20 is an illustrated, self-administered questionnaire comprising 20 short and easy-to-understand questions to assess upper limb disorders. This study aimed to test the reliability, validity, and responsiveness of Hand20.

METHODS

Eighty-five patients with three upper limb disorders (51 with trigger finger, 29 with ulnar impaction syndrome, and five with carpal tunnel syndrome) completed Hand20, the Japanese Society for Surgery of the Hand version of the Disabilities of the Arm, Shoulder, and Hand questionnaire (DASH-JSSH), and the 36-Item Short-Form Health Survey (SF-36). Reliability was assessed by internal consistency. To test the validity, a factor analysis of Hand20 was performed and the correlation coefficients between Hand20 and DASH-JSSH and those between Hand20 and SF-36 were calculated. Responsiveness was evaluated in 47 patients with trigger finger as the standardized response mean and effect size after treatment.

RESULTS

A Cronbach's α coefficient of 0.967 confirmed the unidimensionality of Hand20. The correlation coefficient between Hand20 and DASH-JSSH was 0.84. The correlations between Hand20 and the SF-36 subscales ranged from -0.236 to -0.596. Moderate correlations were observed for "Role-physical" (r = -0.596) and "Bodily pain" (r = -0.557). The correlation between the Hand20 and "Physical functioning" was weak (r = -0.313). The standardized response mean and effect size of Hand20 was 1.50 and 1.60, respectively.

CONCLUSIONS

The Hand20 has evaluation capacities equivalent to those of DASH-JSSH. There was a moderate correlation between Hand20 and SF-36.

Для цитирования: Moritomo Hisao, Imaeda Toshihiko, Gotani Hiroyuki, Momose Toshimitsu, Abe Yukio, Oi Hiroyuki, Omokawa Shohei, Sawaizumi Takuya, Nemoto Koichi, Functional Evaluation Committee of Japanese Society for Surgery of Hand. Reliability of the Hand20 questionnaire: comparison with the 36-Item Short-Form Health Survey.. Hand surgery : an international journal devoted to hand and upper limb surgery and related research : journal of the Asia-Pacific Federation of Societies for Surgery of the Hand. 2014. DOI: 10.1142/s0218810414500014.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.