MedElevator Войти в исследования
← Поиск публикаций

DOI 10.2147/idr.s543137

Медицинская библиотека · Infection and drug resistance · 2025

Development and Evaluation of a Handmade Lateral Flow Immunoassay for the Rapid Detection of Carbapenem-producing Gram-Negative Bacteria in China.

Zhang Cai-Yun, Ji Jun, Chen Xiu-Zhen, Wang Wei-Xiao, Chen Wei, Cao Xiao-Li

СтатьяПеревод в очереди

Аннотация

BACKGROUND

The global dissemination of carbapenemase-producing organisms (CPOs) poses a critical public health threat. Rapid, cost-effective diagnostic tools are urgently needed to guide antimicrobial therapy and mitigate resistance spread.

OBJECTIVE

This study aimed to develop and evaluate a lateral flow immunoassay (LFIA)-based workflow for the rapid detection of carbapenemases (KPC, IMP, NDM, VIM, and OXA-48) in clinical settings.

MATERIALS AND

METHODS

The LFIA strips targeting carbapenemases were handmade in-house using monoclonal antibodies specific to five prevalent subtypes: KPC, IMP, NDM, VIM, and OXA-48. Performance was validated using 26 characterized carbapenemase-producing Enterobacterales (CPE) strains (10 KPC, 5 IMP, 7 NDM, 1 VIM, and 3 OXA-48 producers) and 105 clinical isolates. Among them, strains positive for carbapenemase by LFIA were further confirmed by Next-generation sequencing (NGS) and PCR, and their carbapenem susceptibility was determined by the Vitek2 Antibiotics Susceptibility Test (AST). Diagnostic metrics were further assessed through limit of detection (LoD), cross-reactivity, and interference studies. The overall workflow for the development and evaluation of the LFIA is presented in Figure 1.

RESULTS

The LFIA demonstrated 100% sensitivity in detecting all 26 CPE strains. Among 105 clinical isolates, 44 were identified as CPO strains, with strong concordance to PCR/NGS results (discrepancies in 8 isolates observed between PCR and NGS). The assay exhibited high sensitivity (100%), specificity (100%), positive predictive value (PPV, 93.2%), negative predictive value (NPV, 100%), and accuracy (97.1%). The LoD for each carbapenemase type was established. No cross-reactivity with non-target bacteria or interference from clinical substances was observed. The workflow achieved results in 15 minutes at a lower cost than conventional methods.

CONCLUSION

This LFIA-based workflow provides a rapid, reliable, and cost-effective solution for detecting CPOs, particularly for critically ill patients or in resource-limited settings. Its implementation could enhance therapeutic decision-making and antimicrobial stewardship.

Для цитирования: Zhang Cai-Yun, Ji Jun, Chen Xiu-Zhen, Wang Wei-Xiao, Chen Wei, Cao Xiao-Li. Development and Evaluation of a Handmade Lateral Flow Immunoassay for the Rapid Detection of Carbapenem-producing Gram-Negative Bacteria in China.. Infection and drug resistance. 2025. DOI: 10.2147/idr.s543137.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.