Медицинская библиотека · Kidney international reports · 2024

Ex vivo C5b-9 Deposition Test to Monitor Complement Activity in Clinical and Subclinical Atypical Hemolytic Uremic Syndrome and in Transplantation-Associated Thrombotic Microangiopathy.

Martin Maria, Llorens-Cebria Carmen, León-Román Juan, Perurena-Prieto Janire, Perez-Beltran Víctor, Saumell Silvia, Torres Irina B, Agraz Irene, Sellarès Joana, Ramos Natàlia, Bestard Oriol, López Mercedes, Moreso Francesc, Ariceta Gema, Soler Maria José, Hernandez-Gonzalez Manuel, Jacobs-Cachá Conxita

СтатьяПеревод в очереди

Аннотация

INTRODUCTION

Atypical hemolytic uremic syndrome (aHUS) is a complement system (CS)-mediated ultrarare disease that manifests as thrombotic microangiopathy (TMA) with preferential small kidney vessels involvement. Transient CS activation is also observed in secondary TMA or in patients at risk of developing aHUS. There is no gold standard test to monitor disease activity; however, the ex vivo C5b-9 deposition test seems to be a good approach.

METHODS

We assessed the C5b-9 deposition induced by serum samples of patients with aHUS (n = 8) and with TMA associated with kidney (n = 2), lung (n = 1) or hematopoietic stem cell (HSC) transplantation (HSCT, n = 2) during the acute phase of the disease or in remission. As control for transplant-associated TMA (TA-TMA), we analyzed samples of clinically stable kidney and HSC-transplanted patients without signs of TMA. In addition, we studied 1 child with genetic risk of aHUS during an acute infection.

RESULTS

In the acute disease phase or in patients with disease activity despite C5 blockade, a significant increase of C5b-9 deposition was detected. In all patients with clinical response to C5 blockade but one, levels of C5b-9 deposition were within the normal range. Finally, we detected increased C5b-9 deposition levels in an asymptomatic child with genetic risk of aHUS when a concomitant otitis episode was ongoing.

CONCLUSION

The ex vivo C5b-9 deposition test is an auspicious tool to monitor CS activity in aHUS and TA-TMA. In addition, we demonstrate that the test may be useful to detect subclinical increase of CS activity, which expands the spectrum of patients that would benefit from a better CS activity assessment.

Для цитирования: Martin Maria, Llorens-Cebria Carmen, León-Román Juan, Perurena-Prieto Janire, Perez-Beltran Víctor, Saumell Silvia, Torres Irina B, Agraz Irene, Sellarès Joana, Ramos Natàlia, Bestard Oriol, López Mercedes, Moreso Francesc, Ariceta Gema, Soler Maria José, Hernandez-Gonzalez Manuel, Jacobs-Cachá Conxita. Ex vivo C5b-9 Deposition Test to Monitor Complement Activity in Clinical and Subclinical Atypical Hemolytic Uremic Syndrome and in Transplantation-Associated Thrombotic Microangiopathy.. Kidney international reports. 2024. DOI: 10.1016/j.ekir.2024.04.022.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.