MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1002/acr.24734

Медицинская библиотека · Arthritis care & research · 2022

Ultrasonography of Inflammatory and Structural Lesions in Hand Osteoarthritis: An Outcome Measures in Rheumatology Agreement and Reliability Study.

Mathiessen Alexander, Hammer Hilde B, Terslev Lene, Kortekaas Marion C, D'Agostino Maria A, Haugen Ida K, Bruyn George A, Filippou Georgios, Filippucci Emilio, Kloppenburg Margreet, Mancarella Luana, Mandl Peter, Möller Ingrid, Mortada Mohamed A, Naredo Esperanza, Sedie Andrea Delle, Sexton Joseph, Wittoek Ruth, Iagnocco Annamaria, Ellegaard Karen, OMERACT Ultrasound Working Group

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

OBJECTIVE

To standardize and assess the reliability of ultrasonographic assessment of inflammatory and structural lesions in patients with hand osteoarthritis (OA).

METHODS

The Outcome Measures in Rheumatology Ultrasound Working Group selected synovial hypertrophy (SH), joint effusion (JE), and power Doppler (PD) signals as the main inflammatory lesions in hand OA, and suggested osteophytes in the scapho-trapezio-trapezoid (STT) and cartilage defects in the proximal interphalangeal (PIP) joints as novel additions to previous structural scoring systems. A complementary imaging atlas provided detailed examples of the scores. A reliability exercise of static images was performed for the inflammatory features, followed by a patient-based exercise with 6 sonographers testing inflammatory and structural features in 12 hand OA patients. We used Cohen's kappa for intrareader and Light's kappa for interreader reliability for all features except PD, in which prevalence-adjusted bias-adjusted kappa (PABAK) was applied. Percentage agreement was also assessed.

RESULTS

The web-based reliability exercise demonstrated substantial intra- and interreader reliability for all inflammatory features (κ > 0.64). In the patient-based exercise, intra- and interreader reliability, respectively, varied: SH κ = 0.73 and 0.45; JE κ = 0.70 and 0.55; PD PABAK = 0.90 and 0.88; PIP joint cartilage κ = 0.56 and 0.45; and STT osteophytes κ = 0.62 and 0.36. Percentage close agreement was high for all features (>85%).

CONCLUSION

With ultrasound, substantial to excellent intrareader reliability was found for inflammatory features of hand OA. Interreader reliability was moderate, but overall high close agreement between readers suggests that better reliability is achievable after further training. Assessment of osteophytes in the STT joint and cartilage in the PIP joints achieved less reliability and the latter is not endorsed.

Для цитирования: Mathiessen Alexander, Hammer Hilde B, Terslev Lene, Kortekaas Marion C, D'Agostino Maria A, Haugen Ida K, Bruyn George A, Filippou Georgios, Filippucci Emilio, Kloppenburg Margreet, Mancarella Luana, Mandl Peter, Möller Ingrid, Mortada Mohamed A, Naredo Esperanza, Sedie Andrea Delle, Sexton Joseph, Wittoek Ruth, Iagnocco Annamaria, Ellegaard Karen, OMERACT Ultrasound Working Group. Ultrasonography of Inflammatory and Structural Lesions in Hand Osteoarthritis: An Outcome Measures in Rheumatology Agreement and Reliability Study.. Arthritis care & research. 2022. DOI: 10.1002/acr.24734.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.