MedElevator Войти в исследования
← Поиск публикаций

DOI 10.21037/qims-24-729

Медицинская библиотека · Quantitative imaging in medicine and surgery · 2024

Artificial intelligence improves the diagnosis of human leukocyte antigen (HLA)-B27-negative axial spondyloarthritis based on multi-sequence magnetic resonance imaging and clinical features.

Lu Zixiao, Zou Qingqing, Wang Menghong, Han Xinai, Shi Xingliang, Wu Shufan, Xie Zhuoyao, Ye Qiang, Song Liwen, He Yi, Feng Qianjin, Zhao Yinghua

СтатьяПеревод в очереди

Аннотация

BACKGROUND

Axial spondyloarthritis (axSpA) is frequently diagnosed late, particularly in human leukocyte antigen (HLA)-B27-negative patients, resulting in a missed opportunity for optimal treatment. This study aimed to develop an artificial intelligence (AI) tool, termed NegSpA-AI, using sacroiliac joint (SIJ) magnetic resonance imaging (MRI) and clinical SpA features to improve the diagnosis of axSpA in HLA-B27-negative patients.

METHODS

We retrospectively included 454 HLA-B27-negative patients with rheumatologist-diagnosed axSpA or other diseases (non-axSpA) from the Third Affiliated Hospital of Southern Medical University and Nanhai Hospital between January 2010 and August 2021. They were divided into a training set (n=328) for 5-fold cross-validation, an internal test set (n=72), and an independent external test set (n=54). To construct a prospective test set, we further enrolled 87 patients between September 2021 and August 2023 from the Third Affiliated Hospital of Southern Medical University. MRI techniques employed included T1-weighted (T1W), T2-weighted (T2W), and fat-suppressed (FS) sequences. We developed NegSpA-AI using a deep learning (DL) network to differentiate between axSpA and non-axSpA at admission. Furthermore, we conducted a reader study involving 4 radiologists and 2 rheumatologists to evaluate and compare the performance of independent and AI-assisted clinicians.

RESULTS

NegSpA-AI demonstrated superior performance compared to the independent junior rheumatologist (≤5 years of experience), achieving areas under the curve (AUCs) of 0.878 [95% confidence interval (CI): 0.786-0.971], 0.870 (95% CI: 0.771-0.970), and 0.815 (95% CI: 0.714-0.915) on the internal, external, and prospective test sets, respectively. The assistance of NegSpA-AI promoted discriminating accuracy, sensitivity, and specificity of independent junior radiologists by 7.4-11.5%, 1.0-13.3%, and 7.4-20.6% across the 3 test sets (all P<0.05). On the prospective test set, AI assistance also improved the diagnostic accuracy, sensitivity, and specificity of independent junior rheumatologists by 7.7%, 7.7%, and 6.9%, respectively (all P<0.01).

CONCLUSIONS

The proposed NegSpA-AI effectively improves radiologists' interpretations of SIJ MRI and rheumatologists' diagnoses of HLA-B27-negative axSpA.

Для цитирования: Lu Zixiao, Zou Qingqing, Wang Menghong, Han Xinai, Shi Xingliang, Wu Shufan, Xie Zhuoyao, Ye Qiang, Song Liwen, He Yi, Feng Qianjin, Zhao Yinghua. Artificial intelligence improves the diagnosis of human leukocyte antigen (HLA)-B27-negative axial spondyloarthritis based on multi-sequence magnetic resonance imaging and clinical features.. Quantitative imaging in medicine and surgery. 2024. DOI: 10.21037/qims-24-729.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.