Impact of training data composition on the generalizability of convolutional neural network aortic cross-section segmentation in four-dimensional magnetic resonance flow imaging.

Manini Chiara, Hüllebrand Markus, Walczak Lars, Nordmeyer Sarah, Jarmatz Lina, Kuehne Titus, Stern Heiko, Meierhofer Christian, Harloff Andreas, Erley Jennifer, Kelle Sebastian, Bannas Peter, Trauzeddel Ralf Felix, Schulz-Menger Jeanette, Hennemuth Anja

СтатьяМногоцентровое исследованиеСравнительное исследованиеПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

BACKGROUND

Four-dimensional cardiovascular magnetic resonance flow imaging (4D flow CMR) plays an important role in assessing cardiovascular diseases. However, the manual or semi-automatic segmentation of aortic vessel boundaries in 4D flow data introduces variability and limits the reproducibility of aortic hemodynamics visualization and quantitative flow-related parameter computation. This paper explores the potential of deep learning to improve 4D flow CMR segmentation by developing models for automatic segmentation and analyzes the impact of the training data on the generalization of the model across different sites, scanner vendors, sequences, and pathologies.

METHODS

The study population consists of 260 4D flow CMR datasets, including subjects without known aortic pathology, healthy volunteers, and patients with bicuspid aortic valve (BAV) examined at different hospitals. The dataset was split to train segmentation models on subsets with different representations of characteristics, such as pathology, gender, age, scanner model, vendor, and field strength. An enhanced three-dimensional U-net convolutional neural network (CNN) architecture with residual units was trained for time-resolved two-dimensional aortic cross-sectional segmentation. Model performance was evaluated using Dice score, Hausdorff distance, and average symmetric surface distance on test data, datasets with characteristics not represented in the training set (model-specific), and an overall evaluation set. Standard diagnostic flow parameters were computed and compared with manual segmentation results using Bland-Altman analysis and interclass correlation.

RESULTS

The representation of technical factors, such as scanner vendor and field strength, in the training dataset had the strongest influence on the overall segmentation performance. Age had a greater impact than gender. Models solely trained on BAV patients' datasets performed well on datasets of healthy subjects but not vice versa.

CONCLUSION

This study highlights the importance of considering a heterogeneous dataset for the training of widely applicable automatic CNN segmentations in 4D flow CMR, with a particular focus on the inclusion of different pathologies and technical aspects of data acquisition.

Для цитирования: Manini Chiara, Hüllebrand Markus, Walczak Lars, Nordmeyer Sarah, Jarmatz Lina, Kuehne Titus, Stern Heiko, Meierhofer Christian, Harloff Andreas, Erley Jennifer, Kelle Sebastian, Bannas Peter, Trauzeddel Ralf Felix, Schulz-Menger Jeanette, Hennemuth Anja. Impact of training data composition on the generalizability of convolutional neural network aortic cross-section segmentation in four-dimensional magnetic resonance flow imaging.. Journal of cardiovascular magnetic resonance : official journal of the Society for Cardiovascular Magnetic Resonance. 2024. DOI: 10.1016/j.jocmr.2024.101081.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.