MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1002/jor.25730

Медицинская библиотека · Journal of orthopaedic research : official publication of the Orthopaedic Research Society · 2023

Is augmented femoral lateral plating with helically shaped medial plates biomechanically advantageous over straight medial plates?

Pastor Torsten, Zderic Ivan, Drenchev Ludmil, Skulev Hristo K, Berk Till, Beeres Frank J P, Link Björn-Christian, Gueorguiev Boyko, Stoffel Karl, Knobe Matthias

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

Dual plating of comminuted distal femoral fractures allows for early patient mobilization. An additional helically shaped medial plate avoids the medial vital structures of the thigh. The aim of this study is to investigate the biomechanical competence of an augmented lateral locking compression plate distal femur (LCP-DF) using an additional straight versus a helically shaped medial LCP of the same length. Ten pairs of human cadaveric femora were instrumented with a lateral anatomical 15-hole LCP-DF. Following, they were pairwise instrumented with either an additional medial straight 14-hole LCP (group 1) or a 90°-helical shape LCP (group 2). All specimens were biomechanically tested under quasi-static and progressively increasing combined cyclic axial and torsional loading until failure. Initial interfragmentary axial displacement and flexion under static compression were significantly smaller in group 1 (0.11 ± 0.12 mm and 0.21 ± 0.10°) versus group 2 (0.31 ± 0.14 mm and 0.68 ± 0.16°), p ≤ 0.007. Initial varus deformation under static compression remained not significantly different between group 1 (0.57 ± 0.23°) and group 2 (0.75 ± 0.34°), p = 0.085. Flexion movements during dynamic loading were significantly bigger in group 2 (2.51 ± 0.54°) versus group 1 (1.63 ± 1.28°), p = 0.015; however, no significant differences were observed in terms of varus, internal rotation, and axial and shear displacements between the groups, p ≥ 0.204. Cycles to failure and load at failure were higher in group 2 (25,172 ± 6376 and 3017 ± 638 N) compared to group 1 (22,277 ± 4576 and 2728 ± 458 N) with no significant differences between them, p = 0.195. From a biomechanical perspective, helical double plating may be considered a useful alternative to straight double plating, demonstrating ameliorated damping capacities during flexion deformation and safer application as the medial neurovascular structures of the thigh are avoided.

Для цитирования: Pastor Torsten, Zderic Ivan, Drenchev Ludmil, Skulev Hristo K, Berk Till, Beeres Frank J P, Link Björn-Christian, Gueorguiev Boyko, Stoffel Karl, Knobe Matthias. Is augmented femoral lateral plating with helically shaped medial plates biomechanically advantageous over straight medial plates?. Journal of orthopaedic research : official publication of the Orthopaedic Research Society. 2023. DOI: 10.1002/jor.25730.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.