MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.ultrasmedbio.2013.01.005

Медицинская библиотека · Ultrasound in medicine & biology · 2013

The value of high-frequency ultrasonographic imaging for quantifying trigger digits: a correlative study with clinical findings in patients with different severity grading.

Chiang Chen-Hao, Kuo Li-Chieh, Kuo Yao-Lung, Wu Kuo-Chen, Shao Chung-Jung, Chern Tai-Chang, Jou I-Ming

Сравнительное исследованиеСтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

Trigger digit is recognized as thickening and constriction of the flexor tendon sheath at the base of digits. This study investigates the correlation between the severity grading of trigger digits and clinical findings from high-frequency ultrasonography. We measured and compared thicknesses, areas and pathological changes of the flexor digit tendons among total, contracture and noncontracture trigger digits and noninvolved contralateral digits. Forty-seven patients with 55 idiopathic trigger digits (36 contracture and 19 noncontracture) and 55 noninvolved contralateral digits were examined using high-frequency ultrasonography. The thickness of the flexor tendons was measured in a longitudinal plane at the A1 pulley: Inlet (metacarpal head-neck junction), Outlet (proximal phalangeal base-shaft junction) and Interpulley (middle of Inlet and Outlet). The cross-sectional and extratendinous tissue areas of the flexor tendons in a transverse plane at the point of Interpulley were measured. Pathological changes including irregular internal echotextures, fluid collection, dominant A1 pulley and abnormal metacarpophalangeal joint were analyzed. All thicknesses and areas of total and contracture trigger digits were significantly greater than those of noninvolved contralateral digits (p < 0.05), whereas no significant difference was observed in noncontracture trigger digits. The pathological changes were all significantly different from noninvolved contralateral digits in total, contracture and noncontracture trigger digits (p < 0.05). In contracture and noncontracture trigger digits, there were significant differences only in the thickness of the Inlet and the pathological change of the dominant A1 pulley (p < 0.05). In conclusion, the results of the ultrasonographic measurements and findings provided evidence of Notta's node and correlated with clinical findings and severity grades.

Для цитирования: Chiang Chen-Hao, Kuo Li-Chieh, Kuo Yao-Lung, Wu Kuo-Chen, Shao Chung-Jung, Chern Tai-Chang, Jou I-Ming. The value of high-frequency ultrasonographic imaging for quantifying trigger digits: a correlative study with clinical findings in patients with different severity grading.. Ultrasound in medicine & biology. 2013. DOI: 10.1016/j.ultrasmedbio.2013.01.005.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.