MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1097/bsd.0b013e318218a4f7

Медицинская библиотека · Journal of spinal disorders & techniques · 2012

Feasibility of C2 translaminar screw as an alternative or salvage of C2 pedicle screws in atlantoaxial instability.

Park Jae Suk, Cho Dae-Chul, Sung Joo Kyung

СтатьяПеревод в очереди

Аннотация

STUDY

DESIGN

A retrospective outcome study.

OBJECTIVE

The purpose of this study was to analyze the clinical outcomes of our experience with the C2 translaminar screw technique and evaluate its feasibility as an alternative or salvage of the pedicle screw.

SUMMARY OF BACKGROUND DATA: Pedicle screws are the most biomechanically stable screws for use in atlantoaxial fixation. However, in cases with elevated risk of neurovascular complications or failure of screw insertion attempts, a reliable alternative technique is required.

METHODS

Fourteen patients with atlantoaxial instability underwent posterior fixation with C2 translaminar screws. Indications included traumatic instability, atlantoaxial subluxation, os odontoideum, and fusion failure after anterior fixation of a type II odontoid process fracture. A total of 26 screws were inserted and all patients were assessed both clinically and radiographically.

RESULTS

No procedure-related complications or hardware failures were observed during the follow-up. Postoperative computed tomographic scans revealed laminar breach in 3 patients and none of these resulted in neurological symptoms. Radiographically demonstrated bony fusion was established in 11 patients (91.7%) at follow-up over 6 months, and 5 patients with initial neurological deficit demonstrated at least 1 grade improvement by Frankel grade.

CONCLUSIONS

C2 translaminar screws provide surgeons with an expanded option for posterior fusion in high cervical lesions. This technique is safe and easy to adopt with a favorable rate of successful fusion. We believe that preoperative planning using computed tomographic scan is mandatory and use of an additional connector may reduce the stress and strain of the screws.

Для цитирования: Park Jae Suk, Cho Dae-Chul, Sung Joo Kyung. Feasibility of C2 translaminar screw as an alternative or salvage of C2 pedicle screws in atlantoaxial instability.. Journal of spinal disorders & techniques. 2012. DOI: 10.1097/bsd.0b013e318218a4f7.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.