MedElevator Войти в исследования
← Поиск публикаций

DOI 10.3171/2023.4.focus23149

Медицинская библиотека · Neurosurgical focus · 2023

Bilateral sacroiliac joint fusion in long constructs using self-harvesting porous S2-alar iliac screws with an integrated tulip: technical considerations and early clinical and radiographic experience.

Alan Nima, Lee Katriel E, Zhou James J, Farber S Harrison, DiDomenico Joseph D, O'Neill Luke K, Turner Jay D, Uribe Juan S

СтатьяПеревод в очереди

Аннотация

OBJECTIVE

The incidence of sacroiliac joint (SIJ) dysfunction after lumbosacral fusion is high. Upfront bilateral SIJ fusion using novel fenestrated self-harvesting porous S2-alar iliac (S2AI) screws could reduce the incidence of SIJ dysfunction and need for subsequent SIJ fusion. In this study, the authors report their early clinical and radiographic results of SIJ fusion using this novel screw.

METHODS

The authors began using self-harvesting porous screws in July 2022. This is a retrospective review of consecutive patients at a single institution who underwent long thoracolumbar surgery with extension to the pelvis using this porous screw. Radiographic parameters of regional and global alignment were collected preoperatively and at the time of last follow-up. The incidence of intraoperative complications and need for revision were collected. The incidences of mechanical complications, including screw breakage, implant loosening/pullout, and screw cap dislocation at the time of last follow-up were also collected.

RESULTS

Ten patients with a mean age of 67 years were included, 6 of whom were male. Seven patients had a thoracolumbar construct with extension to the pelvis. Three patients had upper instrumented vertebrae at the proximal lumbar spine. Intraoperative breach was not encountered in any of the patients (0%). Postoperatively, 1 patient (10%) had screw breakage at the neck of the tulip of the modified iliac screw discovered at routine follow-up without clinical sequalae.

CONCLUSIONS

Use of self-harvesting porous S2AI screws incorporated into long thoracolumbar constructs was safe and feasible, demanding unique technical considerations. Long-term clinical and radiographic follow-up with a large patient cohort is necessary to determine their durability and efficacy to achieve SIJ arthrodesis and prevent SIJ dysfunction.

Для цитирования: Alan Nima, Lee Katriel E, Zhou James J, Farber S Harrison, DiDomenico Joseph D, O'Neill Luke K, Turner Jay D, Uribe Juan S. Bilateral sacroiliac joint fusion in long constructs using self-harvesting porous S2-alar iliac screws with an integrated tulip: technical considerations and early clinical and radiographic experience.. Neurosurgical focus. 2023. DOI: 10.3171/2023.4.focus23149.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.