Midterm outcomes of a short-cemented bipolar radial head arthroplasty, in a cohort of 56 cases with minimum 2-years follow-up.

Le Mapihan Marie, Amsallem Lior, Ing David, Masméjean Emmanuel H

СтатьяПеревод в очереди

Аннотация

BACKGROUND

Radial head prostheses are used in comminuted radial head fractures for elbow stabilisation when reduction and internal fixation is not possible. Several implant designs exist, but no large series exist about a short-cemented and bipolar implant.

HYPOTHESIS: The hypothesis was that this prosthesis design shows good clinical, functional, and radiological results, with acceptable rate of complications.

STUDY

DESIGN

This retrospective study included the prostheses with bipolar design and short-cemented stem (Evolutive™), with a minimum 2-years follow-up.

MATERIALS AND

METHODS

All prosthesis implanted in our Traumatology Center were included, with minimum 2-years follow-up. The evaluation consisted of a clinical and functional evaluation, associated with an independent radiographic assessment. All complications were listed, as long as rate and reasons for implant removal.

RESULTS

Fifty-six implants were studied with a mean follow-up of 64.9months (24 to 119). Fifty-three cases were acute injuries with 16% isolated radial head fractures and 76% complex elbow injury such as ulno-humeral, radio-ulnar or longitudinal forearm instability. Fifty (89%) implants were still in place at last follow-up. The main reason for implant removal was during arthrolysis procedure. Ranges of motion were: 126° in flexion, 9° of extension loss, 76° of pronation and 79° of supination. Mean Mayo Elbow Performance Index was 84.1 with 72% of excellent or good results, and the median quick-DASH was rated 18.2. Radiographic evaluation found 12% significant ulno-humeral arthtitis, 64% capitellar osteopenia and 12% loosening. We recorded 5% of implant-related complications.

DISCUSSION: The short-cemented stem bipolar radial head prosthesis presents clinical and functional results similar to other radial head prosthesis with low incidence of elbow arthritis, when treating both isolated radial head fracture or complexes elbow injury. This implant should therefore be valid for treating comminuted radial head fractures in all types of traumatological injuries.

LEVEL OF EVIDENCE: IV; Retrospective cohort study.

Для цитирования: Le Mapihan Marie, Amsallem Lior, Ing David, Masméjean Emmanuel H. Midterm outcomes of a short-cemented bipolar radial head arthroplasty, in a cohort of 56 cases with minimum 2-years follow-up.. Orthopaedics & traumatology, surgery & research : OTSR. 2023. DOI: 10.1016/j.otsr.2023.103716.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.