BACKGROUND

The present study aimed to evaluate the safety of robot-assisted screw placement in 125 cases after introducing a spinal robotics system and to identify the situations where deviation was likely to occur.

METHODS

The subjects were 125 consecutive patients who underwent robotic-assisted screw placement using a spinal robotics system (Mazor X Stealth Edition, Medtronic) from April 2021 to January 2023. The 1048 screws placed with robotic assistance were evaluated. We investigated intraoperative adverse events of the robotics system and complications occurring within 30 days after surgery. We evaluated screw accuracy and deviation and compared them for vertebral levels, screw insertion methods (open traditional pedicle screw [Open-PS], cortical bone trajectory screw [CBT], percutaneous pedicle screw [PPS], and S2 alar iliac screw [S2AIS]), diagnosis, and phases of surgical cases.

RESULTS

The deviation rate of robotic-assisted screw placement for spine surgery was 2.2%. Complications were reoperation due to implant-related neurological deficit in 0.8% and surgical site infection in 0.8%. There was significant difference in the deviation rate between vertebral levels. The deviation rate of the T1-T4 level was high at 10.0%. There was significant difference in the deviation rate between Open-PS, CBT, PPS, and S2AIS. The PPSs had a high deviation rate of 10.3%. The deviation rates were not significantly different between patients with and without deformity. The deviation rate did not change depending on the experience of surgical cases, and the deviation rate was favorable from the onset.

CONCLUSION

Although the robotic-assisted screw placement was safe, we should be extra vigilant when placing screws in the upper thoracic region (deviation rate 10.0%) and when using PPSs (deviation rate 10.3%).

Для цитирования: Akazawa Tsutomu, Torii Yoshiaki, Ueno Jun, Umehara Tasuku, Iinuma Masahiro, Yoshida Atsuhiro, Tomochika Ken, Ohtori Seiji, Niki Hisateru. Safety of robotic-assisted screw placement for spine surgery: Experience from the initial 125 cases.. Journal of orthopaedic science : official journal of the Japanese Orthopaedic Association. 2023. DOI: 10.1016/j.jos.2023.06.003.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.