MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.jpba.2016.09.045

Медицинская библиотека · Journal of pharmaceutical and biomedical analysis · 2016

Selective functional activity measurement of a PEGylated protein with a modification-dependent activity assay.

Weber Alfred, Engelmaier Andrea, Mohr Gabriele, Haindl Sonja, Schwarz Hans Peter, Turecek Peter L

СтатьяПеревод в очереди

Аннотация

BAX 855 (ADYNOVATE) is a PEGylated recombinant factor VIII (rFVIII) that showed prolonged circulatory half-life compared to unmodified rFVIII in hemophilic patients. Here, the development and validation of a novel assay is described that selectively measures the activity of BAX 855 as cofactor for the serine protease factor IX, which actives factor X. This method type, termed modification-dependent activity assay, is based on PEG-specific capture of BAX 855 by an anti-PEG IgG preparation, followed by a chromogenic FVIII activity assay. The assay principle enabled sensitive measurement of the FVIII cofactor activity of BAX 855 down to the pM-range without interference by non-PEGylated FVIII. The selectivity of the capture step, shown by competition studies to primarily target the terminal methoxy group of PEG, also allowed assessment of the intactness of the attached PEG chains. Altogether, the modification-dependent activity not only enriches, but complements the group of methods to selectively, accurately, and precisely measure a PEGylated drug in complex biological matrices. In contrast to all other methods described so far, it allows measurement of the biological activity of the PEGylated protein. Data obtained demonstrate that this new method principle can be extended to protein modifications other than PEGylation and to a variety of functional activity assays.

Для цитирования: Weber Alfred, Engelmaier Andrea, Mohr Gabriele, Haindl Sonja, Schwarz Hans Peter, Turecek Peter L. Selective functional activity measurement of a PEGylated protein with a modification-dependent activity assay.. Journal of pharmaceutical and biomedical analysis. 2016. DOI: 10.1016/j.jpba.2016.09.045.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.