MedElevator Войти в исследования
← Поиск публикаций

DOI 10.3389/fbioe.2026.1758146

Медицинская библиотека · Frontiers in bioengineering and biotechnology · 2026

Finite element biomechanics of novel intramedullary nails with varying diameters for intertrochanteric femoral fractures with lateral wall injury.

Wu En, Tang Zhongjian, Wang Liucheng, Liu Haitao, Peng Zhiwei, Liang Yonghui

СтатьяПеревод в очереди

Аннотация

OBJECTIVE

This study aimed to compare the fixation performance differences between the traditional proximal femoral nail antirotation (PFNA), "II" proximal femoral bionic nail (PFBN), and proximal femoral total bionic nail (PFTBN) in the treatment of intertrochanteric femoral fractures complicated by lateral wall injury using finite element analysis. Additionally, it intended to explore the biomechanical effects of reamed versus unreamed techniques on these novel intramedullary nail devices.

METHODS

Validated FEA models of intertrochanteric fractures (lateral wall injury) were constructed with 9 mm (unreamed) and 11 mm (reamed) medullary canals, followed by implantation of PFNA, "II" PFBN, or PFTBN. Under a vertical load of 2100 N, Von Mises Stress (VMS) and displacement of the femur and implants were quantified.

RESULTS

Under a vertical load of 2100 N, in the unreamed condition, the PFTBN exhibited the lowest peak stress and displacement among the three devices, followed by the "II" PFBN, while the traditional PFNA showed the poorest performance. After reaming, all three implants demonstrated increased peak stress and slightly elevated peak displacement; however, PFTBN remained the most stable. Notably, reaming significantly reduced the overall peak stress of the femur. Collectively, PFTBN more effectively reduced the stress and displacement of both the femur and the implant under both reamed and unreamed conditions, with "II" PFBN showing intermediate efficacy. Both novel devices provided superior internal fixation stability compared to PFNA, which may contribute to a reduced risk of postoperative complications.

CONCLUSION

PFTBN outperforms "II" PFBN and PFNA in load/shear resistance for intertrochanteric fractures with lateral wall injury, regardless of reaming. "II" PFBN also shows superior stability to PFNA. Reaming increases nail-bone contact, mitigating femoral stress concentration and refracture risk. Both PFTBN and "II" PFBN are reliable fixation options with promising clinical utility.

Для цитирования: Wu En, Tang Zhongjian, Wang Liucheng, Liu Haitao, Peng Zhiwei, Liang Yonghui. Finite element biomechanics of novel intramedullary nails with varying diameters for intertrochanteric femoral fractures with lateral wall injury.. Frontiers in bioengineering and biotechnology. 2026. DOI: 10.3389/fbioe.2026.1758146.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.