MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1097/brs.0b013e3182672307

Медицинская библиотека · Spine · 2013

Reliability of quantitative magnetic resonance imaging methods in the assessment of spinal canal stenosis and cord compression in cervical myelopathy.

Karpova Alina, Arun Ranganathan, Davis Aileen M, Kulkarni Abhaya V, Mikulis David J, Sooyong Chua, Rabin Doron, Craciunas Sorin, Smith Sean R, Hansen Mitchell A, George Joshi, Fehlings Michael G

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

STUDY

DESIGN

Prospective, blinded reliability study of quantitative magnetic resonance imaging (MRI) measures in patients with cervical myelopathy.

OBJECTIVE

To assess the intra- and interobserver reliability of commonly used quantitative MRI measures such as transverse area (TA) of spinal cord, compression ratio (CR), maximum canal compromise (MCC), and maximum spinal cord compression (MSCC).

SUMMARY OF BACKGROUND DATA: There is no consensus on an optimal quantitative MRI method(s) in assessing canal stenosis and cord compression.

METHODS

Seven surgeons performed measurements on 17 digital MR images, on 4 separate occasions. The degree of stenosis was evaluated by measuring TA and CR on axial T2, MCC, and MSCC on midsagittal T1- and T2-weighted MRI sequences, respectively. Statistical analyses included repeated-measures analysis of variance and intraclass correlation coefficients (ICCs).

RESULTS

The mean ± SD for intraobserver ICC was 0.88 ± 0.1 for MCC, 0.76 ± 0.08 for MSCC, 0.92 ± 0.07 for TA, and 0.82 ± 0.13 for CR. In addition, the interobserver ICC was 0.75 ± 0.04 for MCC, 0.79 ± 0.09 for MSCC, 0.80 ± 0.05 for CR, and 0.86 ± 0.03 for TA. Higher degree of canal compromise (MCC) was associated with lower modified version of Japanese Orthopaedic Association Scale score (P = 0.05). Also, a strong association was found between MSCC and lower modified version of Japanese Orthopaedic Association Scale score, greater number of steps, and longer walking time (P < 0.05).

CONCLUSION

All 4 measurement techniques demonstrated a good to moderately high degree of intra- and interobserver reliability. Highest reliability was noted in the assessment of T2-weighted sequences and axial MRI. Our results show that the measurements of MCC, MSCC, and CR are sufficiently reliable and correlate well with clinical severity of cervical myelopathy.

Для цитирования: Karpova Alina, Arun Ranganathan, Davis Aileen M, Kulkarni Abhaya V, Mikulis David J, Sooyong Chua, Rabin Doron, Craciunas Sorin, Smith Sean R, Hansen Mitchell A, George Joshi, Fehlings Michael G. Reliability of quantitative magnetic resonance imaging methods in the assessment of spinal canal stenosis and cord compression in cervical myelopathy.. Spine. 2013. DOI: 10.1097/brs.0b013e3182672307.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.