MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s00586-023-07746-w

Медицинская библиотека · European spine journal : official publication of the European Spine Society, the European Spinal Deformity Society, and the European Section of the Cervical Spine Research Society · 2023

Minimally invasive transforaminal lumbar interbody fusion by a novel two-medium compatible bichannel endoscopy system, technique note and preliminary clinical results.

Gong Haoyu, Fan Yunshan, Zhao Yingchuan, Chen Fangjing, Chen Jia, Yan Huang, Gu Guangfei, Wang Chuanfeng, Ni Haijian, He Shisheng

СтатьяПеревод в очереди

Аннотация

PURPOSE: Our team designed a novel two-medium compatible bichannel endoscopy system for spinal surgery, V-shape bichannel endoscopy (VBE) system. Hereby, this study will introduce minimally invasive transforaminal lumbar interbody fusion (TLIF) with VBE system and report its preliminary clinical results.

METHODS

Fifty-two participants, who accepted VBE-assisted TLIF surgery (VBE-TLIF) in our hospital were included in this study. The duration of operation, off-bed time, and days of hospitalization were recorded. Besides, the patient's preoperative and postoperative pain were evaluated via visual analog scale (VAS), the functional status was evaluated via Oswestry dysfunction index (ODI) and modified MacNab criteria. Patients were asked to follow-up in the outpatient department at the 3rd, 6th, 12th, and 24th month after surgery. X-ray or CT was examined to evaluate the internal fixation position and interbody fusion result.

RESULTS

All patients received unilateral decompression with an average operation duration of 178.49 ± 27.49 min. After the surgery, their VAS score of leg pain and back pain reduced significantly. At the last follow-up, the VAS score of leg pain and back pain was 0.80 ± 0.69 and 0.86 ± 0.75 separately. The difference shows statistically significant with p < 0.05. At the last follow-up, the ODI was 15.20 ± 5.75. According to modified MacNab criteria, 39 patients rated their function as excellent, and 10 patients were good. The overall satisfaction rate reached 94%.

CONCLUSION

The VBE system reported in the current study can complete TLIF surgery safely and effectively.

Для цитирования: Gong Haoyu, Fan Yunshan, Zhao Yingchuan, Chen Fangjing, Chen Jia, Yan Huang, Gu Guangfei, Wang Chuanfeng, Ni Haijian, He Shisheng. Minimally invasive transforaminal lumbar interbody fusion by a novel two-medium compatible bichannel endoscopy system, technique note and preliminary clinical results.. European spine journal : official publication of the European Spine Society, the European Spinal Deformity Society, and the European Section of the Cervical Spine Research Society. 2023. DOI: 10.1007/s00586-023-07746-w.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.