MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.arthro.2022.10.009

Медицинская библиотека · Arthroscopy : the journal of arthroscopic & related surgery : official publication of the Arthroscopy Association of North America and the International Arthroscopy Association · 2022

Postless Hip Distraction Systems Decrease the Amount of Traction Force Needed to Obtain Adequate Hip Distraction Versus a Conventional Post Hip Distractor.

O'Neill Dillon C, Featherall Joseph, Dowdle S Blake, Frederiksen Hunter G, Cassidy Benjamin P, Adeyemi Temitope F, Maak Travis G

СтатьяПеревод в очереди

Аннотация

PURPOSE: To directly compare hip distraction distance and traction force data for hip arthroscopy performed using a post-basedsystem versus a postless system.

METHODS

Adult patients undergoing primary hip arthroscopy for femoroacetabular impingement were prospectively enrolled. Before March 26, 2019, arthroscopy was performed using a post-based system. After this date, the senior author converted to using a postless system. Intraoperative traction force and fluoroscopic distraction distance were measured to calculate hip stiffness coefficients at holding traction (k-hold) and maximal traction (k-max). We used multivariable regression analysis to determine whether postless arthroscopy was predictive of lower stiffness coefficients when controlling for other relevant patient-specific factors.

RESULTS

Hip arthroscopy was performed with a post-based system in 105 patients and with a postless system in 51. Mean holding traction force (67.5 ± 14.0 kilograms-force [kgf] vs 55.8 ± 15.3 kgf) and mean maximum traction force (96.0 ± 16.6 kgf vs 69.9 ± 14.1 kgf) were significantly lower in the postless group. On multivariable analysis, postless traction was an independent predictor of decreased k-hold (β = -31.4; 95% confidence interval, -61.2 to -1.6) and decreased k-max (β = -90.4; 95% confidence interval, -127.8 to -53.1). Male sex, Beighton score of 0, and poor hamstring flexibility were also predictors of increased k-hold and k-max in the multivariable model.

CONCLUSIONS

Postless traction systems decrease the amount of traction force required for adequate hip distraction for both maximal and holding traction forces when compared with post-based systems. Postless traction systems may help further reduce distraction-type neurologic injuries and pain after hip arthroscopy by lowering the traction force required to safely distract the hip.

LEVEL OF EVIDENCE: Level III, prospective cohort-historical control comparative study.

Для цитирования: O'Neill Dillon C, Featherall Joseph, Dowdle S Blake, Frederiksen Hunter G, Cassidy Benjamin P, Adeyemi Temitope F, Maak Travis G. Postless Hip Distraction Systems Decrease the Amount of Traction Force Needed to Obtain Adequate Hip Distraction Versus a Conventional Post Hip Distractor.. Arthroscopy : the journal of arthroscopic & related surgery : official publication of the Arthroscopy Association of North America and the International Arthroscopy Association. 2022. DOI: 10.1016/j.arthro.2022.10.009.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.