OBJECTIVE
To investigate the anthropometric parameters that can accurately predict the diameter of the hamstring tendon graft, and to examine the correlation between disease etiology, duration, and graft diameter.
METHODS
A retrospective analysis was conducted on data from 166 patients who underwent anterior cruciate ligament reconstruction using hamstring tendon autografts (semitendinosus and gracilis tendon) between January 2013 and December 2023. The cohort conprised 135 males and 31 females;the age ranged from 14 to 62 years old with an average of (28.87±10.46) years old. Pearson correlation coefficients, partial correlation coefficients, and stepwise multiple linear regression analysis were utilized to elucidate the relationship between the outcome variable (diameter of hamstring tendon grafts) and predictive variables (e.g., height).
RESULTS
Correlation analysis revealed significant associations between the diameter of hamstring tendon grafts and height (r=0.379, P<0.001), weight (r=0.225, P=0.002), male gender (r=0.302, P<0.001), age(r=-0.218, P=0.002), and sports injury etiology (r=0.167, P=0.016). No significant correlations were found with surgical side, body mass index (BMI), or injury duration (P>0.05). Stepwise multiple linear regression analysis using a backward elimination method indicated that height was the sole significant predictive variable (R2=0.144, P<0.001), with the optimal predictive equation being:Graft size =2.636+0.029×Height (cm). Partial correlation analysis, after controlling for height, showed no significant association between age, gender, weight, and injury etiology with graft diameter.
CONCLUSION
Height is an effective predictive factor for the diameter of autologous hamstring tendon grafts. Factors such as gender, age, surgical side, body weight, and BMI are not influential to the diameter of the hamstring tendon grafts. Under the condition of the same height, there is no significant difference in the influence of these factors on the graft diameter. Preoperative physical activity level and the duration of injury do not significantly affect the diameter of the hamstring tendon grafts obtained during surgery. It is recommended to use the formula 'Graft Diameter=2.636 + 0.029 × Height (cm)' for preoperative prediction.