PURPOSE: The aim of this study was to introduce biportal endoscopic extraforaminal lumbar interbody fusion (BE-EFLIF), which involves insertion of a cage through a more lateral side as compared to the conventional corridor of transforaminal lumbar interbody fusion. We described the advantages and surgical steps of 3D-printed porous titanium cage with large footprints insertion through multi-portal approach, and preliminary results of this technique.

METHODS

This retrospective study included 12 consecutive patients who underwent BE-EFLIF for symptomatic single-level lumbar degenerative disease. Clinical outcomes, including a visual analog scale (VAS) for back and leg pain and the Oswestry disability index (ODI), were collected at preoperative months 1 and 3, and 6 months postoperatively. In addition, perioperative data and radiographic parameters were analyzed.

RESULTS

The mean patient age, follow-up period, operation time, and volume of surgical drainage were 68.3 ± 8.4 years, 7.6 ± 2.8 months, 188.3 ± 42.4 min, 92.5 ± 49.6 mL, respectively. There were no transfusion cases. All patients showed significant improvement in VAS and ODI postoperatively, and these were maintained for 6 months after surgery (P < 0.001). The anterior and posterior disc heights significantly increased after surgery (P < 0.001), and the cage was ideally positioned in all patients. There were no incidences of early cage subsidence or other complications.

CONCLUSIONS

BE-EFLIF using a 3D-printed porous titanium cage with large footprints is a feasible option for minimally invasive lumbar interbody fusion. This technique is expected to reduce the risk of cage subsidence and improve the fusion rate.

Для цитирования: You Ki-Han, Hwang Jae-Yeun, Hong Seok-Ho, Kang Min-Seok, Park Sang-Min, Park Hyun-Jin. Biportal endoscopic extraforaminal lumbar interbody fusion using a 3D-printed porous titanium cage with large footprints: technical note and preliminary results.. Acta neurochirurgica. 2023. DOI: 10.1007/s00701-023-05605-7.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.