Sonographically guided intrasheath percutaneous release of the first annular pulley for trigger digits, part 2: randomized comparative study of the economic impact of 3 surgical models.
Аннотация
OBJECTIVES
Trigger digit surgery can be performed by an open approach using classic open surgery, by a wide-awake approach, or by sonographically guided first annular pulley release in day surgery and office-based ambulatory settings. Our goal was to perform a turnover and economic analysis of 3 surgical models.
METHODS
Two studies were conducted. The first was a turnover analysis of 57 patients allocated 4:4:1 into the surgical models: sonographically guided-office-based, classic open-day surgery, and wide-awake-office-based. Regression analysis for the turnover time was monitored for assessing stability (R(2) < .26). Second, on the basis of turnover times and hospital tariff revenues, we calculated the total costs, income to cost ratio, opportunity cost, true cost, true net income (primary variable), break-even points for sonographically guided fixed costs, and 1-way analysis for identifying thresholds among alternatives.
RESULTS
Thirteen sonographically guided-office-based patients were withdrawn because of a learning curve influence. The wide-awake (n = 6) and classic (n = 26) models were compared to the last 25% of the sonographically guided group (n = 12), which showed significantly less mean turnover times, income to cost ratios 2.52 and 10.9 times larger, and true costs 75.48 and 20.92 times lower, respectively. A true net income break-even point happened after 19.78 sonographically guided-office-based procedures. Sensitivity analysis showed a threshold between wide-awake and last 25% sonographically guided true costs if the last 25% sonographically guided turnover times reached 65.23 and 27.81 minutes, respectively. However, this trial was underpowered.
CONCLUSIONS
This trial comparing surgical models was underpowered and is inconclusive on turnover times; however, the sonographically guided-office-based approach showed shorter turnover times and better economic results with a quick recoup of the costs of sonographically assisted surgery.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.