MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s00264-023-05816-8

Медицинская библиотека · International orthopaedics · 2023

Dislocation and survival rate of dual mobility cups in revision total hip arthroplasty in patients with high risk of instability.

Ameztoy Gallego Juan, Cruz Pardos Ana, Gomez Luque Javier, Cuadrado Rubio Luis Eduardo, Fernández Fernández Ricardo

СтатьяПеревод в очереди

Аннотация

PURPOSE: Instability remains as an unsolved complication after revision total hip arthroplasty (rTHA). Dual mobility (DM) cups have decreased dislocation rate in rTHA; however, there are few clinical studies that evaluate the risk of dislocation after rTHA in patients with high risk of instability.

METHODS

Between 2007 and 2019, 95 consecutive rTHA using a DM cup, in 93 patients with instability risk factors were retrospectively reviewed. Instability risk factors were defined as follows: deficient abductor mechanism (22.1%), previous dislocation (68.4%), Paprosky 3 acetabular bone defect (21.1%), neuromuscular disease (4.2%), lumbar spine arthrodesis (6.3%), and more than one previous surgery (33.6%). Mean follow-up was 4.3 ± 2.4 years. Clinical and radiographic parameters were reported. DM cup survival was determined using a Kaplan-Meier analysis with re-revision for any cause as the end-point. Surgical complications and re-dislocation rate was recorded.

RESULTS

Seven DM cups were re-revised; three due to aseptic loosening, three due to peri-prosthetic joint infection (PJI), and one due to instability. At seven years follow-up, the survival rate of the DM cup using re-revision for any reason as the end-point was 82.4% (95% confidence interval, 66.4-98.4%). There were 12 (12.6%) complications: two (2.1%) dislocations, six (6.3%) PJI, four (4.2%) peri-prosthetic fractures.

CONCLUSION

Our findings suggest DM cups are effective reducing dislocation rate in rTHA in patients with a high risk of instability, without increasing early aseptic loosening and with a low rate of dislocation. Nevertheless, longer follow-up is needed to confirm implant stability and dislocation rates in the long term.

Для цитирования: Ameztoy Gallego Juan, Cruz Pardos Ana, Gomez Luque Javier, Cuadrado Rubio Luis Eduardo, Fernández Fernández Ricardo. Dislocation and survival rate of dual mobility cups in revision total hip arthroplasty in patients with high risk of instability.. International orthopaedics. 2023. DOI: 10.1007/s00264-023-05816-8.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.