MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1002/adhm.202403000

Медицинская библиотека · Advanced healthcare materials · 2024

Structured Polymers Enable the Sustained Delivery of Glucocorticoids within the Intra-Articular Space.

Crastin Ana, Martin Claire S, Suresh Sai, Davies Scott P, Kearns Daniel, Parlak Ahsen, Adcock Holly, Filer Andrew, Jones Simon W, Raza Karim, Moakes Richard Ja, Grover Liam M, Hardy Rowan S

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

Intra-articular glucocorticoid injections are effective in controlling inflammation and pain in arthritides but restricted by short duration of action and risk of joint degeneration. Controlled drug release using biocompatible hydrogels offers a unique solution, but limitations of in situ gelation restrict their application. Gellan sheared hydrogels (GSHs) retain the advantages of hydrogels, however their unique microstructures lend themselves to intra-articular application - capable of shear thinning under force but restructuring at rest to enhance residence. This study examined GSHs for extended intra-articular glucocorticoid delivery of prednisolone (10 mg mL-1); demonstrating links between material mechanics, steroid release, and preclinical assessment of efficacy in synoviocyte culture and transgenic(TNF)197Gkl (TNFtg) murine model of arthritis. GSHs demonstrated sustained release, with typical Fickian profiles over 18 days. Moreover, systems showed good stability under extended culture, with inherent cell-compatibility and suppression of inflammatory synoviocyte activation. In TNFtg animals, GSHs suppressed synovitis (70.08%, p < 0.05), pannus formation (45.01%, p < 0.05), and increased articular cartilage (82.23%, p < 0.05) relative to vehicle controls. The extended profile of steroid release from injectable GSH formulations holds promise in the treatment and management of inflammatory arthritides such as rheumatoid and osteoarthritis, representing a step-change in intra-articular drug delivery to suppress long-term joint inflammation.

Для цитирования: Crastin Ana, Martin Claire S, Suresh Sai, Davies Scott P, Kearns Daniel, Parlak Ahsen, Adcock Holly, Filer Andrew, Jones Simon W, Raza Karim, Moakes Richard Ja, Grover Liam M, Hardy Rowan S. Structured Polymers Enable the Sustained Delivery of Glucocorticoids within the Intra-Articular Space.. Advanced healthcare materials. 2024. DOI: 10.1002/adhm.202403000.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.