MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s00330-011-2105-7

Медицинская библиотека · European radiology · 2011

Magnetic resonance 4D flow characteristics of cerebrospinal fluid at the craniocervical junction and the cervical spinal canal.

Bunck Alexander C, Kröger Jan-Robert, Jüttner Alena, Brentrup Angela, Fiedler Barbara, Schaarschmidt Frank, Crelier Gerard R, Schwindt Wolfram, Heindel Walter, Niederstadt Thomas, Maintz David

СтатьяПеревод в очереди

Аннотация

OBJECTIVES

To evaluate the applicability of 4D phase contrast (4D PC) MR imaging in the assessment of cerebrospinal fluid dynamics in healthy volunteers and patients with lesions at the craniocervical junction or the cervical spinal canal.

METHODS

Ten healthy volunteers and four patients with lesions including Chiari I malformation and cervical canal stenoses were examined by a cardiac-gated 4D PC imaging sequence on 1.5T MRI. Phase contrast images were postprocessed allowing for flow quantification and flow pathline visualisation. Velocity data were compared with conventional axial 2D phase contrast images.

RESULTS

The 4D PC sequence allowed for flow quantification and visualisation in all individuals. Bland-Altman analysis showed good agreement of 2D and 4D PC velocity data. In healthy volunteers, CSF flow was homogeneously distributed in the anterior and anterolateral subarachnoid space with the flow directed caudally during systole and cranially during diastole. Flow velocities were closely related to the width of the subarachnoid space. Patients showed grossly altered CSF flow patterns with formation of flow jets with increased flow velocities.

CONCLUSIONS

4D PC MR imaging allows for a detailed assessment of CSF flow dynamics helping to distinguish physiological from complex pathological flow patterns at the craniocervical junction and the cervical spine.

Для цитирования: Bunck Alexander C, Kröger Jan-Robert, Jüttner Alena, Brentrup Angela, Fiedler Barbara, Schaarschmidt Frank, Crelier Gerard R, Schwindt Wolfram, Heindel Walter, Niederstadt Thomas, Maintz David. Magnetic resonance 4D flow characteristics of cerebrospinal fluid at the craniocervical junction and the cervical spinal canal.. European radiology. 2011. DOI: 10.1007/s00330-011-2105-7.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.