European spine journal : official publication of the European Spine Society, the European Spinal Deformity Society, and the European Section of the Cervical Spine Research Society · 2024

Heterotopic ossification, osteolysis and implant failure following cervical total disc replacement with the M6-C™ artificial disc.

СтатьяПоддержка исследования: вне правительства СШАНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Häckel Sonja, Gaff Jessica, Pabbruwe Moreica, Celenza Alana, Kern Michael, Taylor Paul, Miles Andrew, Cunningham Greg

Аннотация

INTRODUCTION: A recent study reported a 34% mid-term revision rate after M6-C™ cervical total disc replacement (CTDR) for wear-related osteolysis. Here, we aim to investigate the prevalence, risk factors, and radiographic characteristics of periprosthetic bony changes and implant failure of the M6-C™ artificial disc.

METHODS: We retrospectively analysed radiographic (conventional X-ray, CT scan) and clinical outcomes (EQ-5D-5L, Neck Disability Index (NDI), and Visual Analog Scale (VAS) for neck and arm pain) data collected during routine follow-up of patients who underwent CTDR with the M6-C™ between 2011 and 2015.

RESULTS: In total, 85 patients underwent CTDR with the M6-C™. Follow-up data were available for 43 patients (54% female, mean age 44 years) with 50 implants and a mean follow-up of 8.1 years (6.5-11 years). Implant failure with the presence of severe osteolysis was identified in 5 (12%) patients who were all male (p = 0.016) and implanted at the C5/6 level (p = 0.11). All failed implants required revision surgery. The overall prevalence of osteolysis was 44% (22/50 implants) and 34% (17/50 implants) for significant heterotopic ossification. Patients with high-grade osteolysis showed higher VAS arm pain (p = 0.05) and lower EQ-5D-VAS health VAS (p = 0.03).

CONCLUSION: We report a lower reoperation rate for failed M6-C™ implants than previously published, but confirmed that osteolysis and heterotopic ossification are common following CTDR with the M6-C™ and may be asymptomatic. Therefore, we strongly recommend ongoing clinical and radiographic monitoring after CTDR with the M6-C™, particularly for male patients implanted at the C5/6 level.