MedElevator Войти в исследования
← Поиск публикаций

DOI 10.2214/ajr.10.5769

Медицинская библиотека · AJR. American journal of roentgenology · 2011

Utility of sonographic measurement of the common tensor tendon in patients with lateral epicondylitis.

Lee Min Hee, Cha Jang Gyu, Jin Wook, Kim Byung Sung, Park Jai Soung, Lee Hae Kyung, Hong Hyun Sook

СтатьяПеревод в очереди

Аннотация

OBJECTIVE

The purpose of this article is to evaluate prospectively the utility of sonographic measurements of the common extensor tendon for diagnosing lateral epicondylitis.

SUBJECTS AND

METHODS

Forty-eight patients with documented lateral epicondylitis and 63 healthy volunteers were enrolled and underwent ultrasound of the elbow joint. The common extensor tendon overlying the bony landmark was scanned transversely, and the cross-section area and the maximum thickness were measured. Clinical examination was used as the reference standard in the diagnosis of lateral epicondylitis. Data from the patient and control groups were compared with established optimal diagnostic criteria for lateral epicondylitis using receiver operating characteristic curves. Qualitative evaluation with grayscale ultrasound was also performed on patients and healthy volunteers.

RESULTS

The common extensor tendon was significantly thicker in patients with lateral epicondylitis than in control subjects (p < 0.01). Tendon thickness greater than 4.2 mm (sensitivity, 78.4%; specificity, 95.2%; accuracy, 87.7%) and area larger than or equal to 32 mm(2) (sensitivity, 86.3%; specificity, 82.5%; accuracy, 84.2%) were highly predictive of lateral epicondylitis. For qualitative evaluation with gray-scale ultrasound, overall sensitivity, specificity, and accuracy values in the diagnosis of lateral epicondylitis were 76.5%, 76.2%, and 76.3%, respectively.

CONCLUSION

The quantitative sonographic measurements had an excellent diagnostic performance for lateral epicondylitis, as well as good or excellent interreader agreement. A common extensor tendon cross-section area greater than or equal to 32 mm(2) and a thickness of 4.2 mm correlated well with the presence of lateral epicondylitis. However, further prospective study is necessary to determine whether quantitative ultrasound with these cutoff values can improve the accuracy of the diagnosis of lateral epicondylitis.

Для цитирования: Lee Min Hee, Cha Jang Gyu, Jin Wook, Kim Byung Sung, Park Jai Soung, Lee Hae Kyung, Hong Hyun Sook. Utility of sonographic measurement of the common tensor tendon in patients with lateral epicondylitis.. AJR. American journal of roentgenology. 2011. DOI: 10.2214/ajr.10.5769.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.