MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s00586-011-1701-1

Медицинская библиотека · European spine journal : official publication of the European Spine Society, the European Spinal Deformity Society, and the European Section of the Cervical Spine Research Society · 2011

Kinematic evaluation of the adjacent segments after lumbar instrumented surgery: a comparison between rigid fusion and dynamic non-fusion stabilization.

Morishita Yuichiro, Ohta Hideki, Naito Masatoshi, Matsumoto Yoshiyuki, Huang George, Tatsumi Masato, Takemitsu Yoshiharu, Kida Hirotaka

Сравнительное исследованиеСтатьяПеревод в очереди

Аннотация

The aim of the current study was to evaluate changes in lumbar kinematics after lumbar monosegmental instrumented surgery with rigid fusion and dynamic non-fusion stabilization. A total of 77 lumbar spinal stenosis patients with L4 degenerative spondylolisthesis underwent L4-5 monosegmental posterior instrumented surgery. Of these, 36 patients were treated with rigid fusion (transforaminal lumbar interbody fusion) and 41 with dynamic stabilization [segmental spinal correction system (SSCS)]. Lumbar kinematics was evaluated with functional radiographs preoperatively and at final follow-up postoperatively. We defined the contribution of each segmental mobility to the total lumbar mobility as the percent segmental mobility [(sagittal angular motion of each segment in degrees)/(total sagittal angular motion in degrees) × 100]. Magnetic resonance imaging was performed on all patients preoperatively and at final follow-up postoperatively. The discs were classified into five grades based on the previously reported system. We defined the progress of disc degeneration as (grade at final follow-up) - (grade at preoperatively). No significant kinematical differences were shown at any of the lumbar segments preoperatively; however, significant differences were observed at the L2-3, L4-5, and L5-S1 segments postoperatively between the groups. At final follow-up, all of the lumbar segments with rigid fusion demonstrated significantly greater disc degeneration than those with dynamic stabilization. Our results suggest that the SSCS preserved 14% of the kinematical operations at the instrumented segment. The SSCS may prevent excessive effects on adjacent segmental kinematics and may prevent the incidence of adjacent segment disorder.

Для цитирования: Morishita Yuichiro, Ohta Hideki, Naito Masatoshi, Matsumoto Yoshiyuki, Huang George, Tatsumi Masato, Takemitsu Yoshiharu, Kida Hirotaka. Kinematic evaluation of the adjacent segments after lumbar instrumented surgery: a comparison between rigid fusion and dynamic non-fusion stabilization.. European spine journal : official publication of the European Spine Society, the European Spinal Deformity Society, and the European Section of the Cervical Spine Research Society. 2011. DOI: 10.1007/s00586-011-1701-1.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.