MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s00586-022-07280-1

Медицинская библиотека · European spine journal : official publication of the European Spine Society, the European Spinal Deformity Society, and the European Section of the Cervical Spine Research Society · 2022

Application of electromagnetic navigation in endoscopic transforaminal lumbar interbody fusion: a cohort study.

Zhang Hao, Xu Derong, Wang Chao, Zhu Kai, Guo Jianwei, Zhao Chong, Han Jialuo, Liu Houchen, Ma Xuexiao, Zhou Chuanli

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

STUDY

DESIGN

Clinical retrospective cohort study.

OBJECTIVES

To explore the application of the electromagnetic navigation system in Endo-TLIF.

MATERIALS AND

METHODS

From May 2019 to March 2020, 76 patients with single-segment lumbar spondylolisthesis treated by electromagnetic navigation-assisted Endo-TLIF (NE group) and conventional Endo-TLIF (CE group) were enrolled in the study. Time of pedicle screw implantation, entire operation time, the number of intraoperative X-ray fluoroscopy exposures, total blood loss, incision length, ambulation time, accuracy of pedicle screws, complications, visual analog scale for back and leg pain, Oswestry Disability Index, Japanese Orthopedic Association score and postoperative fusion rates were recorded, respectively.

RESULTS

There were no significant differences in preoperative demographics between the NE and CE groups (P > 0.05). The mean number of intraoperative X-ray fluoroscopy exposures, guidewires insertion, entire operation time, total blood loss and adjustment rate of screws in the NE group were significantly less compared with the CE group (P < 0.05, respectively). There were no significant differences in clinical parameters between the two groups at different time points in the follow-up period (P > 0.05). There was no statistical difference in fusion rates between the two groups. In addition, one case of cage subsidence was observed after surgery in the CE group.

CONCLUSION

Electromagnetic navigation systems could be applied throughout the entire surgical course and ameliorate the shortcomings of the conventional Endo-TLIF technique to reduce radiation exposure, improve accuracy, avoid repetitive operations and shorten surgery time and the required learning curve of the procedure.

LEVEL OF EVIDENCE I: Diagnostic: individual cross-sectional studies with consistently applied reference standard and blinding.

Для цитирования: Zhang Hao, Xu Derong, Wang Chao, Zhu Kai, Guo Jianwei, Zhao Chong, Han Jialuo, Liu Houchen, Ma Xuexiao, Zhou Chuanli. Application of electromagnetic navigation in endoscopic transforaminal lumbar interbody fusion: a cohort study.. European spine journal : official publication of the European Spine Society, the European Spinal Deformity Society, and the European Section of the Cervical Spine Research Society. 2022. DOI: 10.1007/s00586-022-07280-1.